Preparing The Appliance; Mounting The Appliance - FocalPoint REFLECTION F500079 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8.0 PREPARING THE APPLIANCE

Gas connection :The
heater
gas
inlet
connection is 3/8"
NPT at the regulator,
located below the
burner, in the center of
the heater.
Reflection models :
There are six possible
entry points for the gas
supply pipework to
Figure 1
enter the appliance
Reflection models
firebox. These entry
points are 'knock out'
type holes (shown in
figure 1).
Neon, Athos and
Scandium models :
There are four possible
entry points for the gas
supply pipework to
enter the appliance
firebox. These entry
points are 'knock out'
type holes (shown in
figure 2).
Figure 2
Non-concealed
gas
Neon, Athos, Scandium models
connections may be
made using the entry
points on the base of the firebox. A concealed gas connection may be
made using the knock out hole in the centre back of the firebox. Select the
most appropriate entry point and knock out the relevant hole.
If a concealed gas connection is to be made, the supply pipe should always
be sleeved through walls and floors using the shortest possible route.
For concealed supply pipe routing, pipes must (where possible) be vertical
and providing there is sufficient wall thickness available, they should be
placed in pipe chases. Horizontal pipe runs should be avoided. Prior to
chasing a solid wall, an inspection should be made to note the proximity of
any cables/sockets outlets which may already be buried. Pipes must be
secured using suitable clips and protected against corrosion. Ideally factory
finished protected pipework and fittings should be used. Joints should be
kept to a minimum and compression fittings must not be used. The
pipework installation must be tested for soundness before any protection is
applied and/or the pipework and fittings are buried.
Reflection models ; At
Figure 3
this stage it is necessary
to assemble the rear
frame of the appliance.
Unpack the four frame
sections and lay face
down on a soft surface
taking
care
not
to
damage the painted
finish. Using the eight no.
8 self tapping screws
provided, fix the frame
pieces
together
as
shown in figure 3, making sure that the edges align neatly. Fit the rear
frame to the firebox as shown in figure 4.The decorative front frame
assembly is fitted after the main firebox has been fitted to the wall.
Neon models : At this stage it is necessary
to assemble the rear frame of the appliance.
The rear frame is attached to the firebox
using four self tapping screws (two each
side) as shown in figure 5.

9.0 MOUNTING THE APPLIANCE

WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY
INTO THE FIREPLACE. AVOID ANY DRAFTS THAT ALTER
BURNER FLAME PATTERNS.
After having selected the final mounting position of the appliance, tak-
ing into account the site requirements as specified in section 7 of these
instructions, the integrity of the wall, and the feasibility of the proposed
supply pipe routing, the firebox of appliance may be secured to the
wall. A full size fitting template is supplied to assist with this.
Mark the positions on the wall as shown as relevant to the particular
model. If the appliance is to be mounted on the inner leaf of a con-
ventional cavity wall, or a solid wall, drill four holes using a 1/4"
F860033 ISSUE A - 24/4/06
POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL
WALL MOUNTED VENT FREE
FITTING TEMPLATE
COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED
PLANTILLA PARA LA
INSTALACION DE
CHIMENEAS DE PARED SIN
SALIDA DE HUMOS
FOCAL POINT
WALL MOUNTED
CATALYTIC VENT FREE
GAS FIRE RANGE
FITTING TEMPLATE
DO NOT RECESS OR
INSET ANY PART OF
THE FIRE.
CONCEALED GAS INLET
ENTRADA DE GAS OCULTA
(TODOS LOS MODELOS)
CONCEALED GAS INLET
ENTRADA DE GAS OCULTA
REFLECTION, ATHOS,
NEON, SCANDIUM
IMPORTANT
THIS FIRE IS TO BE WALL HUNG ONLY. DO NOT RECESS OR INSET ANY PAR T OF THE FIRE.
THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY. DO NOT INSTALL THE FIRE WITH THIS TEMPLATE IN PLACE.
IMPORTANTE
ESTE APA RATO UNICAMENTE DEBE SER COLGADO EN UNA PARE D. NO EMPOTRE NINGUN ELEMEN TO DE ESTA CHIMENEA.
ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION. RETIRE LA PLAN TILLA ANTES DE C OLOCAR LA C HIMENEA.
masonry bit. Insert the fiber wall plugs provided.
If the appliance is to be mounted on a dry lined wall or a timber framed
construction wall then special cavity screw fixings will be required
which are not supplied with this product. These should be constructed
from metal and not plastic.
5
Figure 4
16 (406mm)
"
13.8 (350mm)
"
FIXING POINTS:
PUNTOS DE SUJECION:
PLASMA, CAPELLA, RADIUM
WHEN MOUNTING PLATE IS NOT USED
SI NO SE UTILIZA LA PLACA DE MONTAJE
REFLECTION, ATHOS, NEON, SCANDIUM
AND PLASMA / RADIUM
MOUNTING PLATE
PLACA DE MONTAJE
FOCAL POINT
PLANTILLA PARA LA
INSTALACION DE LA
GAMA DE CHIMENEAS
DE GAS CATALITICAS
DE PARED SIN SALIDA
DE HUMOS
NO EMPOTRE NINGUN
ELEMENTO DE ESTA
CHIMENEA
(ALL MODELS)
PIERCE TEMPLATE
TO MARK HOLE
POSITION
ON WALL X 4
(ALL MODELS)
PERFORE LA
PLANTILLA PARA
MARCAR LA POSICION
DE LOS 4 TALADROS
EN LA PARED
(TODOS LOS MODELOS)
Figure 5
Figure 6

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Neon f500083Athos f500082Scandium f500081

Tabla de contenido