insert the rechargeable batteries and then connect the mains adapter. Then carry
out the settings. These settings will be adopted for all of the occupied charge slots.
However, you can also use and set each charge slot individually.
After you have inserted the rechargeable battery, you have 8 seconds to select the
mode and a further 8 seconds to select the charge current. If there is no input for 8
seconds, the charge process starts automatically with the preset parameters.
In order to change a function for an individual rechargeable battery, remove this briefly
and then insert it again. The display for this rechargeable battery flashes and you can
now make the changes for this individual charge slot with the "MODE" and/or "CURRENT"
buttons, as described above.
If you are charging just one or two rechargeable batteries in the charger and are using
only the two outermost charge bays for this, you can set the charge current to 1500mA
or 1800mA with the "CURRENT" button for the "CHARGE" and "TEST" programs. In this
case, the two inner charge bays will not operate. If you want to charge three or four
rechargeable batteries at the same time, you can set the charge current to 400mA,
600mA or 800mA. With the "DISCHARGE" and "REFRESH" programs, the rechargeable
batteries are first discharged and so discharge currents of 200mA, 300mA or 400mA can
be selected here. The subsequent charge process is carried out with twice the current
level than was used for the discharge process.
A few minutes before the rechargeable battery is fully charged, the charger reduces
the charge current to ca. 200mA, regardless of the charge current selected beforehand.
The gentle charging system increases the service life of your rechargeable batteries.
After charging or discharging is complete, the charger waits for a brief period to protect
the rechargeable batteries before continuing with the selected discharge/charge
program.
ATTENTION: Ensure that your rechargeable batteries are designed for the respective
charge current. AAA rechargeable batteries should not be charged with 1500mA or
1800mA! We recommend selecting the maximum charge current (mA) such that it
does not exceed the capacity value (mAh) of your rechargeable battery. This prevents
excessive heat build-up and protects the rechargeable battery.