S&P IDEO 450 ECOWATT Manual Del Usuario página 25

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Outdoor air (ODA):
Install the fresh air intake (wall or roof) at a sufficient distance from any area of
high pollution (trees, exhaust fumes, road, etc).
This duct must be sealed and insulated to prevent condensation.
Supply air (SUP):
To avoid thermal losses and optimize the performance of the installation, it
is recommended to use insulated ducts.
Extract air (ETA):
To avoid thermal losses and optimize the performance of the installation, it
is recommended to use insulated ducts.
Exhaust air (EHA):
This duct must be sealed and insulated to prevent condensation.
By-pass:
The IDEO has a 100% heat exchanger bypass system which allows free
cooling by night. The principle of free-cooling uses free energy from the
outdoor air to ventilate and cool buildings when outdoor air temperature is
lower than the exhaust air temperature.
25

Publicidad

Tabla de contenido
loading

Tabla de contenido