Features
• LCD Digital readout.
• Leakage volume in dangerous zone will sound 'beeping'
and a red lamp flash
• Acoustic alert
• Ergonomic design suitable for the operation of both
hands
• Long battery life
• Never needs recalibration
• High sensitivity
• Excellent reliability and high precision
Technical data
Calibrated . . . . . . . . . . . . . . . . . . . . . . . . . . . at 2450 MHz
Range . . . . . . . . . . . . . . . . . . . . . . . . . . 0- 9.99 mW/cm
Warning value . . . . . . . . . . . . . . . . . . . . . . . 5.0 mW/cm
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1db
Power source . . . . . . . . . . . . . . . . . . . . . . . . . . 9V battery
Battery life . . . . . . . . . . . . . . . . . . . . . . . 1 year minimum,
for routine checking once a month
EN
How to measure
Power on the meter. To keep two inches from the door
seals or the front glass of microwave oven. The values
will display on LCD. If you press the MAX key, the maxi-
mum will hold in the LCD.
When the unit is moved from a warm location to a cold
location (or vice versa), this relocation can lead to con
densation formation on the electronic measuring equip
ment. This physical effect, which cannot be prevented
for constructional reasons, invariably leads to deviations
in measurement. The unit requires an "acclimatisation
time" of approx. 1530 minutes, depending on how high
the temperature differences were, before the measuring
process can be continued.
2
2
ry 2003 concerning old electrical and electronic equipment.
At the end of its life please dispose of this instrument in a
manner appropriate to the relevant legal requirements.
Operating Manual – Mikrowave radiometer
In the European Union electronic equipment
must not be treated as domestic waste, but
must be disposed of professionally in ac-
cordance with Directive 2002/96EU of the Eu-
ropean Parliament and Council of 27th Janua-
B - 3