SOMFY V100 Manual De Instalación página 8

Ocultar thumbs Ver también para V100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
EN
3.1. Installing the door station
These operations must be performed with the power off.
Avoid installing the camera facing a light source, as images of visitors may be impaired.
We recommend that silicon sealant is applied between the rain shield and the wall/pillar (but not below the rain shield) and that the door station is fitted
at a height of approximately 1.60 m.
[1]. Route all the cables into the rain shield.
[2]. Fix the rain shield to the wall/pillar.
[3]. Connect:
• the monitor cable to the first 2 terminals on the door station:
M+ of the monitor to M+ of the door station
M- of the monitor to M- of the door station
• the motorisation cable to the dry contact output (COM and NO) of the door station
• the electric door-opener/lock cable to terminals + and - of the door station.
Note: To feed the cables into the terminals, use a screwdriver to press on the square with the notch, feed the wires in, then release.
[4]. Position the door station in the rain shield.
[5]. Screw the door station to the rain shield using the Allen key.
1
3
Monitor cable
Gate motorisation cable
3.2 Fitting the name tag
[1]. Press and push the left-hand side of the label.
[2]. Using a screwdriver, lift and remove the name tag protector.
[3]. Write your name on the white label using a permanent marker,
then replace the label and its protector in their housing.
3
3. INSTALLING THE DOOR STATION
4
Electric door-
opener/lock cable
2
V100 video entry phone
5
Copyright © 2015 Somfy SAS. All rights reserved.

Publicidad

Tabla de contenido
loading

Tabla de contenido