proBLem
Cause
Coffee overflow-
Probably an excess amount of
ing from the edges
ground coffee has been placed in
of the filter ring.
the filter ring preventing the filter
ring from being correctly tight-
ened into its housing.
Residues of ground coffee have
remained on the gasket of the
filter holder coupling seat.
The hole of the silicone disc (V)
is clogged.
The exit holes of the filter contain-
ing coffee grounds are clogged.
the coffee is not
The holes of the perforated disc
supplied or flows
in the filter holder coupling seat
too slowly.
are clogged.
The exit holes of the filter contain-
ing coffee grounds are clogged.
The coffee blend is ground too
fine.
The coffee blend is pressed down
too much.
The tanks is not inserted well.
The hole of the silicone disc (V)
is clogged.
There is little water and the pump
does not suck it up.
the coffee is too
The blend has been ground too
watery and cold.
coarsely.
Coffee grinder
Impurities are probably mixed
jammed.
with the coffee beans.
18
soLutions
Slowly remove and disconnect the filter holder because any
remaining pressure could cause splashes or squirts. Clean the
coupling seat with a sponge (Fig. 19). Repeat the operation
placing the correct quantity of coffee in the filter.
Clean the seal with a toothpick or a sponge (Fig. 19).
Wash the silicone disc (V) under running water, bending it
slightly on the sides in order to free the centre hole of any resi-
due of coffee that could clog it (Fig. 18).
Slowly remove and disconnect the filter holder because any
remaining pressure could cause splashes or squirts. Clean
the clogged filter hole with a pin. Clean the filter using Ariete
COFFEE CLEAN tabs, following the instructions provided in
the package.
Turn on the machine without the filter holder, making the water
run. If the water still does not come out from all the holes
evenly, carry out the descaling cleaning operation using the
Ariete NOCAL product found at Ariete service centres, follow-
ing the instructions provided in the package.
Slowly remove and disconnect the filter holder because any
remaining pressure could cause splashes or squirts. Clean
the clogged filter hole with a pin. Clean the filter using Ariete
COFFEE CLEAN tabs, following the instructions provided in
the package.
Try using coarser coffee blends.
Tamper coffee inside the filter using less pressure.
Fit the tank securely by pushing it as far as it will go.
Wash the silicone disc (V) under running water, bending it
slightly on the sides in order to free the centre hole of any resi-
due of coffee that could clog it (Fig. 18).
Check that the water level in the tank is correct. If necessary, fill
it with cool tap water.
A more finely ground blend must be used to obtain a more
concentrated and hotter coffee. Anyhow, this problem is eas-
ily solved thanks to the Thermocream® System, which always
guarantees hot coffee accompanied by a reach cream, even
with coarsely ground beans.
Press button (8) to stop grinding. Press coffee grinder release
button (B) and repeatedly turn the container from left to right,
then try again. If the problem persists, try to set coarser grind-
ing (positions 12-14).