Urmet 1158/45 Manual De Instrucciones página 10

Ocultar thumbs Ver también para 1158/45:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

When returning to normal functioning from the
programming phase, the following caption may
appear on the display for few seconds
(abbreviation of 'Store') this can be considered
normal and indicates that the device is permanently
storing the information received. Wait for few
seconds: the caption will disappear and the device
will return to normal functioning.
The individual sub-menus are illustrated below.
STORE USER KEY
Move the key to be stored towards the front panel.
The buzzer will emit a continuous beep and the
display will show the 'number of the key' (i.e. the
position of the key in the memory). To facilitate
management, it is advisable to apply an adhesive
label to the key and to write the 'key number' on
this.
To check that the key has been effectively stored,
move the key towards the front panel: the buzzer
will emit 3 beeps (instead of one) and the display
will show the 'number of the key'.
Repeat as explained above for all user keys to be
stored.
To return to normal functioning, rest a MASTER key
on the front panel.
USER KEY DELETION/REPLACEMENT
To delete a user key that has been lost, you MUST
know the 'number of the key' lost.
Present the MASTER key and hold it in place for at
least 2 seconds. The following will appear on the
display:
and the '0' digit will increase by one unit once a
second, cyclically (i.e. passing from 9 to 0).
Remove the MASTER key when the digit you want
to set is displayed (the fi rst digit of the number of
the lost key).
Repeat the above operations with the MASTER key
10
twice so as to set the other two digits. At this point,
the display will show the number of the lost key that
is to be deleted or replaced.
− If the number entered is not correct (i.e. it does
not correspond to the number of the key to be
deleted), do not perform other operations: after
7 seconds, the device will return to normal
functioning WITHOUT deleting anything.
− If the number set is correct, approach (within 7
seconds) the MASTER key: the buzzer will emit
a beep and the key will be deleted from the
memory. The fl ashing key symbol will be shown
on the display for 7 seconds:
If you want to store a new key and to assign the
SAME 'key number' to this as that you have just
canceled, move the new key towards the front
panel. At this point (or after 7 seconds), the device
will redisplay the key delete/replace invitation
symbol:
Repeat the same operations for all the keys to be
deleted or replaced.
To return to normal functioning, place a MASTER
key close to the front panel.
SETTING OF RELEASE OPEN TIME
When you access this menu, the display indicates
the currently set door release time (factory setting:
't00').
The door release time can be set between 0 and
99 seconds.
Move the MASTER key close to the panel and hold
it in position for at least 2 seconds. The following
will appear on the display:
and the '0' digit will increase by one unit,
approximately once a second, cyclically (i.e. moving
from 9 to 0).
Remove the MASTER key when the digit to be set
is displayed.
Approach and remove the MASTER key so as to
DS1148-001A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1148/45Sintesi steel 1158/45Sintesi 1148/45

Tabla de contenido