Urmet 1158/45 Manual De Instrucciones página 9

Ocultar thumbs Ver también para 1158/45:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1) Power on the device and check that the
following are displayed in sequence:
− the indication (display test);
− the caption (Initialization)
for a few seconds;
− the two-color led changes from red to green
and back to red again in sequence;
− the fl ashing dot, which indicates that the
device is operating correctly, (only if the
display is enabled, with the JP1 jumper in
position 'D').
2) Press the rear red button briefl y: the following
will appear on the display in sequence:
− the SW version of the device (e.g.);
− the indication.
3) Press the rear red button again briefl y to
access the MASTER key storage procedure;
the display will show:
4) Complete the push button panel installation:
all the next operations can be executed by
accessing from the front panel only.
5) From minimum 1 to maximum three MASTER
keys can be defi ned. The MASTER keys will
be used subsequently to program the device,
its parameters and user keys. Once they have
been numbered, the MASTER keys must be
carefully preserved possibly by the installation
technician or administrator of the building: they
can be used for subsequent modifi cations
(addition of new user keys, deletion of lost
keys, etc.).
Present any key to be transformed into a
MASTER key close to the front panel: one of
the three bars will move up to indicate that
the key has been stored as MASTER and the
buzzer will emit a continuous beep.
DS1148-001A
To assure maximum reading effi ciency, the
keys must be presented to the reader with the
side with the Urmet logo or the numeric code
parallel to the front panel.
To check whether a certain key has been stored
as MASTER, move it towards the front panel:
the matching bar (already in the top position)
will fl ash and the buzzer will emit three beeps.
To return to normal functioning, move a MASTER
key to the front panel for approximately 7
seconds. After this time, the display will show
for some seconds:
to indicate that all the MASTER keys have been
stored; the fl ashing dot will then be displayed
(only if the display is enabled with the JP1
jumper in position 'D').
PROGRAMMING
To access programming, move a MASTER key
close to the front panel.
The display will show several screen pages in
sequence. Remove the key from the front panel
when the screen page you wish to access is shown
on the display:
Current software version
(display only)
User key storage/checking
User key deletion/replacement
Set door release time
If, by mistake, you remove the MASTER key at the
wrong time and you enter a sub-menu different from
that set, simply present the MASTER key to the
front panel briefl y to restore normal functioning.
In any case, if no operation is performed for 3
minutes after accessing programming, the device
automatically returns to normal functioning.
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1148/45Sintesi steel 1158/45Sintesi 1148/45

Tabla de contenido