Vimar RS10 Manual Para El Conexionado Y El Uso página 21

Tarjeta con pantalla 230 vac para cancela corredera
Ocultar thumbs Ver también para RS10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
RS10
3.7 - Sensitive edge connection
Programmable input (with edge or photocell not engaged the STPA LED must be ON). if this input trips during opening it immediately reverses the move-
ment for 1.5 seconds and then stops the gate, while during closure it reverses the movement until fully open, see the parameter P06 to select the type
of edge. If not used, jumper between COM. and STPA and set the parameter P06 OFF.
Switch edge connection
STPA input as edge with electromechanical
switch, set parameter P06 OFF.
3.8 - Electrical connection with photo-test function active:
with parameter P08 on 1, the control unit governs the operation of the photocells connected on the PHOTO input, with parameter P08 on 2 the control
unit governs the operation of the photocells connected on the STPA input, with parameter P08 on 3 the control unit governs the operation of the photo-
cells connected on the PHOTO and STPA inputs. Figure 10 shows an example of a connection with photo-test on only for the PHOTO input.
CN1
3.9 - Stop button connection:
Normally closed contact, opening the contact causes the gate to stop and suspends the automatic closing time (when the button is not engaged, the
STOP LED should be lit), if not used then jumper between COM and STOP:
17 18 19 20 21 22 23
CN2
17 18 19 20 21 22 23
Relative sensitive edge connection
17 18 19 20 21 22 23
STPA input as resistive edge at 8.2Kohm,
set parameter P06 ON
RX1
+
-
C NC NA
+
-
COM
FOTO
STPA
17 18 19 20 21 22 23
Normally closed button
EN
8,2 KΩ
RX2
TX1
+
-
C NC NA
+
-
Fig. 12
Fig. 10
TX2
+
-
Fig. 11
19

Publicidad

Tabla de contenido
loading

Tabla de contenido