WARNING: A qualified ser-
vice technician must connect
heater to gas supply. Follow all
local codes.
WARNING: This appliance
requires a 3/8" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.
WARNING: For natural gas,
Never connect heater to private
(non-utility) gas wells. This gas is
commonly known as wellhead gas.
WARNING: Do not over-
tighten gas connections.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
pressure will occur.
CAUTION: For natural gas,
check your gas line pressure
before connecting heater to gas
line. Gas line pressure must be
no greater than 9.5" of water. If
gas line pressure is higher, heater
regulator damage could occur.
14
INSTALLATION
CONNECTING TO GAS SUPPLY
www.sureheat.com
CAUTION: For propane gas,
never connect heater directly
to the gas supply. This heater
requires an external regula-
tor (not supplied). Install the
external regulator between the
heater and propane gas supply.
Gas supplier provides external
regulator for natural gas. The
installer provides the external
regulator for propane gas.
CAUTION: Avoid damage to
regulator. Hold gas regulator
with wrench when connecting
into gas piping and/or fittings.
CAUTION: Use pipe joint
sealant that is resistant to gas
(Propane or Natural Gas).
Before installing heater, make sure you have
the items listed below:
• external regulator for propane unit only
(supplied by installer)
• piping (check local codes)
• sealant (resistant to natural gas and pro-
pane gas)
• equipment shutoff valve*
• test gauge connection*
• sediment trap
• tee joint
• pipe wrench
• flexible gas hose (check local codes)
* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative
to test gauge connection. Purchase the optional
CSA design certified equipment shutoff valve
from your dealer (see Accessories, page 30.
Typical Inlet Pipe Diameters
Use 3/8" black iron pipe or greater. Installa-
tion must include an equipment shutoff valve,
union, and plugged 1/8" NPT tap. Locate NPT
tap within reach for test gauge hook up. NPT
tap must be upstream from heater (see Figure
12, page 15).