EmberGlow VFF15NLA Manual De Instalación Y Funcionamiento Del Propietario página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure
15, page 16).
2. Open main gas valve located on or near
gas meter for natural gas or open propane
supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to control valve (see Figure 16 or
WARNING: Failure to posi-
tion the parts in accordance
with these diagrams or failure
to use only parts specifically
approved with this heater may
result in property damage or
personal injury.
CAUTION: After installation,
and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to high, check
to see if flames contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contact-
ing logs will create soot.
1. Install log #1 on the rear plate as shown
in Figure 19.
2. Install log #2 as shown in Figure 20.
3. Install log #3 and log #4 as shown in
Figure 21.
Rear Plate
Figure 18 - Stove Cabinet
200176-01B
INSTALLATION
17, page 16). Apply a noncorrosive leak
detection fluid to all joints. Bubbles form-
ing show a leak.
5. Correct all leaks at once.
6. Light heater (see Lighting Instructions on
page 19). Check all other internal joints
for leaks.
7. Turn off heater (see To Turn Off Gas Ap-
pliance, page 20).
INSTALLING LOGS
IMPORTANT: Make sure logs do not cover
any burner ports. It is very important to install
the logs exactly as instructed. Do not modify
logs. Use only logs supplied with heater.
Log #3
www.sureheat.com
Log #1
Figure 19 - Installing Log #1
Log #2
Figure 20 - Installing Log #2
Figure 21 - Installing Log #3 & #4
Log #4
17

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido