NATURAL GAS DANGERS AND WARNINGS
Never store or use gasoline or other volatile substance in the vicinity of this fire table.
Natural Gas Connection
Connect a manual shuto valve to gas supply line. Apply sealing compound or pipe thread tape of
the type resistant to the action of Natural Gas on all male pipe threads. Connect the end, with the
quick release connector, of the natural gas hose to manual shut-o valve at the gas supply.
Caution:
!
During any high pressure testing of the gas supply piping system at test pressures in excess
of 1/2 psi (3.5 kPa), the appliance and its individual shuto valve must be disconnected
from the gas supply piping system.
The outdoor fire table must be isolated from the gas supply piping system by closing the
individual manual shuto valve during any pressure testing of the gas supply piping system at
least equal to or less than 1/2 psi (3.5 kPa).
!
Warning:
Burner valves are pre-tested at the factory to operate on natural gas. Do not attempt to
convert or change.