Fan-Speed Controls
FS-5F:
5 A
FSQ-2F:
1.5 A
LTFSQ-2H:
1.5 A
LTFSQ-FH:
1.5 A
Important Notes
Please read before installing.
1.
CAUTION: To avoid overheating and possible damage to other equipment, do not
use to control receptacles, fluorescent lighting fixtures, or transformer-supplied
appliances.
2.
Set multi-speed fans to their highest setting before installing controls.
• Easy-to-follow
3.
When no "ground means" exists within the wallbox, then NEC
Instructions
exception to (b) allows a control without a ground connection, to be installed as a
• Instrucciones
Fáciles de Seguir
replacement. For this type of installation, cap or remove the green control ground
wire. A control installed under this exception (NEC 404.9 exception to (b)) must be
P/N 033-206
provided with a plastic, noncombustible, UL listed wallplate.
4.
Do not use control with a fan and light that operate with the same switch.
5.
For new installations, wire a test switch before installing the control.
6.
Use FSQ-2F and SFSQ-F controls with a ceiling paddle fan only. Use only one ceiling
paddle fan per control.
7.
Use FS-5F controls only with fans marked "Suitable for use with solid-state fan-
speed controls."
8.
Do not wire an FSQ-2F, SFSQ-F or SFSQ-F-HO in a circuit with a GFCI breaker/
receptacle.
9.
Controls may feel warm to the touch during normal operation.
10. Install in accordance with all national and local electrical codes.
11. Clean control with a soft damp cloth only. Do not use any chemical cleaners.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections before wiring
(see below). Use pliers to bend each side section up and down until it breaks off. FS-5F
controls require reduction of their capacity. Refer to chart below for maximum capacity.
FSQ-2F, SFSQ-F and SFSQ-F-HO controls do not require capacity reduction.
model
number
FS-5F
Technical Assistance
If you have questions concerning the installation or operation of this product,
call the Lutron Technical Support Center. Please provide exact model number
when calling.
U.S.A. and Canada (24 hrs/7days)
1.800.523.9466
México
+1.888.235.2910
Other countries 8am – 8pm ET
+1.610.282.3800
Limited Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty
service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
ThiS WarranTy iS in Lieu oF aLL oTher expreSS WarranTieS, and The impLied WarranTy oF
merChanTabiLiTy iS LimiTed To one year From purChaSe. ThiS WarranTy doeS noT Cover The
CoST oF inSTaLLaTion, removaL or reinSTaLLaTion, or damage reSuLTing From miSuSe, abuSe,
or damage From improper Wiring or inSTaLLaTion. ThiS WarranTy doeS noT Cover inCidenTaL
or ConSequenTiaL damageS. LuTron'S LiabiLiTy on any CLaim For damageS ariSing ouT oF or
in ConneCTion WiTh The manuFaCTure, SaLe, inSTaLLaTion, deLivery, or uSe oF The uniT ShaLL
never exCeed The purChaSe priCe oF The uniT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the
exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations
may not apply to you. NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. Lutron is a registered
trademark of Lutron Electronics Co., Inc. © 2010 Lutron Electronics Co., Inc.
English
120 V
60Hz
SFSQ-F:
1.5 A
120 V
60Hz
120 V
60Hz
SFSQ-F-HO:
2 A
120 V
60Hz
120 V
60Hz
120 V
60Hz
2008, 404.9
®
Do Not Remove
Outside Sections
Inside Sections Are
Side Sections Are Removed From
Removed From Each Control
Both Sides Of Middle Control
no Sides
1 Side
2 Sides
removed
removed
removed
5 A
4 A
3 A
Fax +1.610.282.6311
http://www.lutron.com
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 10/10 P/N 033-206 Rev. A
Lutron Technical Support Center
1.800.523.9466
installation
For installations involving more than one control in a wallbox, refer to Multi-Unit
Installations before beginning.
1
Turn power oFF at circuit breaker or remove fuse.
WARNING: Shock Hazard. May result
in serious injury or death. Turn off
power at circuit breaker before
installing the unit.
2
remove switch mounting screws. pull switch from wall.
3
verify your application.
Switch must have two insulated wires connected to two screws and a bare copper
or green wire connected to a green screw. note: Do not connect to a light fixture.
ground
(bare Copper or green Wire)
4
disconnect switch wires.
or
backwired:
Terminal Screws:
insert screwdriver. pull
Turn screws to loosen.
wire out.
important note:
Your wall switch may have two wires attached to the same screw (see illustrations below
for examples). Tape these two wires together before disconnecting. When wiring, connect
wires to the Dimmer the same way they were connected to the switch.
24 hrs / 7 days
www.lutron.com
important Wiring information
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for copper
wire only. For aluminum wire, consult an electrician.
Small:
Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm²) wire
Strip insulation 1/2 in (13 mm) for 16 or 18 AWG
(1.0 mm² or 0.75 mm²) wire
Use to join one 14 AWG (1.5 mm²) supply wire with one
16 or 18 AWG (1.0 mm² or 0.75 mm²) control wire.
Large:
Strip insulation 1/2 in (13 mm) for 10, 12 or 14 AWG
(4, 2.5 or 1.5 mm²) wire
Strip insulation 5/8 in (16 mm) for 16 or 18 AWG
(1.0 mm² or 0.75 mm²) wire
Use to join one or two 12 or 14 AWG (2.5 or 1.5 mm²)
supply wires with one 10, 12, 14, 16, or 18 AWG (4, 2.5,
Small
1.5, 1.0 or 0.75 mm2) control wire.
5
Wire the control:
• Connect the green ground wire on the
control to the green or bare copper
ground wire in the wallbox (see
black
Important Note 3).
• Connect the black wire on the control
to either of the wires removed from
the switch.
• Connect the remaining wire on the
control to the remaining wire removed
from the switch.
black
green
ground
Fan Control
hot
black
black
120 v
60hz
green
Fan
ground
neutral
6
mount and align control. install wallplate.
Start screws.
7
Turn power on.
Twist wire connector
tight.
Be sure no bare wire
is exposed.
Large
align control and
tighten screws.

Publicidad

loading

Resumen de contenidos para Lutron FS-5F

  • Página 1 Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
  • Página 2 (valido solamente en estados unidos, Canada, puerto rico, y el Caribe.) Lutron reparará o reemplazará, a su criterio, cualquier unidad cuyos materiales o fabricación resulten defectuosos en el término de un año después de la fecha de compra. Para obtener servicio de garantía, la unidad debe devolverse al lugar de compra o enviar, con franqueo pago, a Lutron, 7200 Suter Road, Coopersburg, Pennsylvania 18036-1299.