Fan-Speed Controls
~
FS-5F:
5 A
120 V
~
FSq-2F:
1.5 A 120 V
~
LTFSq-2h:
1.5 A 120 V
~
LTFSq-Fh:
1.5 A 120 V
Important Notes
Please read before installing.
1.
CAUTION: To avoid overheating and possible damage to other equipment, do not
use to control receptacles, fluorescent lighting fixtures, or transformer-supplied
appliances.
2. Set multi-speed fans to their highest setting before installing controls.
• easy-to-follow
3. When no "grounding means" exist within the wallbox then the NEC
Instructions
404.9 allows a dimmer without a grounding connection to be installed as a
• Instrucciones
replacement, as long as a plastic, noncombustible wallplate is used. For this type
Fáciles de Seguir
of installation, cap or remove the green ground wire on the dimmer and use an
P/N 030-1051
appropriate wallplate such as Lutron's Claro
4. Do not use control with a fan and light that operate with the same switch.
5. For new installations, wire a test switch before installing the control.
6. Use FSQ-2F and SFSQ-F controls with a ceiling paddle fan only. Use only one ceiling
paddle fan per control.
7. Use FS-5F controls only with fans marked "Suitable for use with solid-state fan-
speed controls."
8. Do not wire an FSQ-2F, SFSQ-F or SFSQ-F-HO in a circuit with a GFCI breaker/
receptacle.
9. Controls may feel warm to the touch during normal operation.
10. Install in accordance with all national and local electrical codes.
11. Clean control with a soft damp cloth only. Do not use any chemical cleaners.
12. For indoor use only.
13. Controls must be mounted vertically. See stamp on control for correct positioning.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections before wiring
(see below). Use pliers to bend each side section up and down until it breaks off. FS-5F
controls require reduction of their capacity. Refer to chart below for maximum capacity.
FSQ-2F, SFSQ-F and SFSQ-F-HO controls do not require capacity reduction.
Model Number
FS-5F
Technical Assistance
If you have questions concerning the installation or operation of this product, call the Lutron
Technical Support Center. Please provide exact model number when calling.
1.800.523.9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1.610.282.3800
Fax +1.610.282.6311
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty
service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
ThIS WARRANTy IS IN LIeU OF ALL OTheR exPReSS WARRANTIeS, AND The IMPLIeD WARRANTy OF MeRChANTABILITy IS LIMITeD
TO ONe yeAR FROM PURChASe. ThIS WARRANTy DOeS NOT COVeR The COST OF INSTALLATION, ReMOVAL OR ReINSTALLATION,
OR DAMAGe ReSULTING FROM MISUSe, ABUSe, OR DAMAGe FROM IMPROPeR WIRING OR INSTALLATION. ThIS WARRANTy DOeS
NOT COVeR INCIDeNTAL OR CONSeqUeNTIAL DAMAGeS. LUTRON'S LIABILITy ON ANy CLAIM FOR DAMAGeS ARISING OUT OF OR IN
CONNeCTION WITh The MANUFACTURe, SALe, INSTALLATION, DeLIVeRy, OR USe OF The UNIT ShALL NeVeR exCeeD The PURChASe
PRICe OF The UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do
not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty
may last, so the above limitations may not apply to you. This product may be covered by one or more of the following U.S.
patents: 4,939,383; 5,191,971 and corresponding foreign patents. Lutron Claro and Fassada are registered trademarks of
Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2008 Lutron Electronics Co., Inc.
English
~
60 Hz
SFSq-F:
1.5 A 120 V
60 Hz
~
60 Hz
SFSq-F-hO:
2 A
120 V
60 Hz
60 Hz
60 Hz
2008, Article
®
or Fassada
series wallplates.
®
®
Do Not Remove
Outside Sections
Inside Sections Are
Side Sections Are
Removed From Each
Removed From Both
Control
Sides Of Middle Control
No Sides
1 Side
2 Sides
Removed
Removed
Removed
5 A
4 A
3 A
Internet: www.lutron.com
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in China. 10/08 P/N 030-1051 Rev. A
Lutron Technical Support Center
Installation
For installations involving more than one control in a wallbox, refer to Multi-Unit
Installations before beginning.
1
WARNING: Turn power OFF at circuit breaker or remove fuse.
2
Removing wallplate and switch.
• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Warning: Before proceeding, verify that
power to the switch is OFF. Otherwise,
death or serious injury could result.
3
Verify your application.
Switch must have two insulated wires connected to two screws and a bare copper
or green wire connected to a green screw.
Note: Do not connect to a light fixture.
Ground
(Bare Copper or Green WIre)
4
Disconnect switch wires.
OR
Terminal Screws:
Backwired:
Turn screws to loosen.
Insert screwdriver. Pull
wire out.
Important Note:
Your wall switch may have two wires attached to the same screw (see illustrations below
for examples). Tape these two wires together before disconnecting. When wiring, connect
wires to the Dimmer the same way they were connected to the switch.
1.800.523.9466
24 hrs / 7 days
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for copper
wire only. For aluminum wire, consult an electrician.
Small:
Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm
Strip insulation 1/2 in (13 mm) for 16 AWG (1.0 mm
(0.75 mm
) wire.
2
Use to join one 14 AWG (1.5 mm
16 AWG (1.0 mm
2
) or 18 AWG (0.75 mm
Large:
Strip insulation 1/2 in (13 mm) for 10 AWG (6 mm
12 AWG (2.5 mm
2
), or 14 AWG (1.5 mm
Strip insulation 5/8 in (16 mm) for 16 AWG
(1.0 mm
) or 18 AWG (0.75 mm
2
Use to join one or two 12 AWG (2.5 mm
14 AWG (1.5 mm
2
) supply wires with one
10 AWG (6 mm
2
), 12 AWG (2.5 mm
(1.5 mm
), 16 AWG (1.0 mm
), or 18 AWG
2
2
(0.75 mm
) control wire.
2
5
Wire the control:
Black
Black
Green
Ground
Fan Control
Live
Black
Black
120 V~
60 hz
Green
Ground
6
Mount and align control. Install wallplate.
Start screws.
7
Turn power ON.
www.lutron.com
2
) wire.
Twist wire
connector tight.
2
) or 18 AWG
Be sure no bare
wire is exposed.
) supply wire with one
2
2
) control wire.
),
2
2
) wire.
) wire.
2
) or
2
2
), 14 AWG
Large
Small
• Connect the green ground wire
on the control to the green or
bare copper ground wire in the
wallbox (see Important Note 3).
• Connect the black wire on the
control to either of the wires
removed from the switch.
• Connect the remaining wire on
the control to the remaining wire
removed from the switch.
Fan
Neutral
Align control and
tighten screws.