4.6. TEMPERATURE CONTROL: MANUAL AND AUTOMATIC
Temperature control and its modification can be done manually or automatically, and can be
performed by pressing key No. 6 when the display is in standby mode or in the heating phase. In this
case one must press the following keys:
Key
1
Exit from the temperature menu and modify the manual / automatic temperature
2
Manual temperature
Automatic temperature
3
Decrease of the pre-selected environmental temperature
4
Increase of the pre-selected environmental temperature
5
Enter into the temperature menu and modify the manual / automatic temperature
6
Example:
• Stand by mode: press key 6 to modify the manual and automatic temperature.
manual temperature
• Press key 2 for
consequently the ventilation (the lowest A1 - A3 the highest), press key 4 to decrease and 5 to increase ventilation.
• Press key 3 to enter the
5 to increase it. The stove will regulate its power to achieve the desired temperature (P) and retain it (P). Press the key
6 to save and exit the menu. To adjust the ventilation (A1 the lowest and A3 the highest) press 4 to decrease and the 5
key to increase.
From this moment, you can turn on the stove, with the saved settings by pressing key 1 for two seconds.
In automatic mode you can activate the option «Comfort Climate» (ask your technical assistance Center) the stove will
automatically turn on when room temperature drops below the preset temperature. We recommend you to use this option
only when the stove is installed on small well insulated rooms since otherwise the ignition and continuous shutdown can
damage its operation.
During the operation: to regulate the operating manual or automatic follow the procedure described in this manual.
IN THE FIRST STOVE IGNITION WE MUST ALWAYS CHECK THAT THE PELLET
In order to follow this operation we must enter the menu use/option/load (paragraph 4.9.)
Example: to enter the user menu, when the screen is on hold, press the button nº 6 until the screen confirms you that you
can enter the menu. With key 2 lower menu until the sub-menu «option», confirm with the button 6; slide menu to the sub
menu 'load' with button 2. With key 5 load for 30 seconds, pressing the key 4 to stop the load.
NOTE:
Flame variations depend on the type of used pellet, normal variability of solid fuel and regular fireplace cleaning. We
recommend you to make automatic cleaning before each ignition.
T.Amb
Auto
Function description
selection, touch 6 to save and exit from menu. To adjust the power and
automatic temperature
COMPARTMENT IS FULL
21ºC
Heat
mode. To adjust the temperature press key 4 to decrease it and key
83