LIST OF PARAMETERS
Parameter
PA
PASSWORD
/
SENSOR PARAMETERS
/C
Temperature offset of room sensor
/2
Reading stability
/3
Reading speed
/4
Virtual sensor
/5
°C /°F (0=°C, 1=°F)
/6
Decimal point (0=yes, 1=no)
r
REGULATOR PARAMETERS
rd
Regulator differential
r1
Minimum allowable set
r2
Maximum allowable set
r3
Enabling Ed alarm (defrosting inhibited as the max duration is
reached,
1
r4
Automatic variation of the set-point during the night (or when the
Curtain-switch is closed, with A4 or A5=7)
r5
Enabling min. and max. temperature monitoring
(0=OFF, 1=ON)
rt
Readout of elapsed time since enabling r5,
Reset of monitored values
rH
Readout of max. temp. monitored
rL
Readout of min. temp. monitored
c
COMPRESSOR PARAMETERS
c0
Delay compressor insertion after
control reset
c1
Minimum time between two insertions
c2
Minimum OFF routine
c3
Minimum ON routine
c4
Safety relay (0=OFF,100=ON).
See duty setting
cc
Continuous cycle duration
c6
Alarm delay after continuous cycle
d
DEFROST PARAMETERS
d0
Type of defrost (0=heater (temp.),1=hot gas (temp.), 2= water or
heater (time), 3= hot gas (time))
dI
Time interval between two defrost cycles
dt
End defrost temperature
dP
Max duration of the defrosting or effective
duration if d0=2 or 3
d4
Defrost after power ON (0=no,1=yes)
d5
Delayed defrost after power ON or
from Multifunct. input (A4 or A5=4)
d6
Blank display during defrost (0=no,1=yes) C
dd
Dripping time
ALARMS AND SIGNALS
BLINKED FUNCTIONING LED
If a LED blinks it means that the corresponding function is delayed by a
timed routine, by another procedure or inhibited by the digital input.
E0 BLINKS: faulty room sensor / E1 BLINKS: faulty defrost sensor
• Used sensor is not compatible with the control
• The sensor cable is interrupted or short circuited
• Faulty sensor: Take out the sensor from the control and verify the
resistance (NTC: 0°C=27K)
AI BLINKS: immediate external alarm
• Check the "Multifunction" input and the A4 parameter
Ad BLINKS: delayed external alarm
• Check the "Multifunction" input and the A4 and A7 parameters
LO BLINKS: low temperature alarm (temperature less than SET-POINT minus AL)
• Verify the AL, Ad and A0 parameters
The alarm disappears as soon as the temperature rises and ranges
within the selected limits
HI BLINKS: high temperature alarm (temperature higher than SET-POINT plus AH)
• Verify the AH, Ad and A0 parameters
The alarm disappears as soon as the temperature decreases and
ranges within the selected limits
ALCO CONTROLS, Heerstr. 111, D-71332 Waiblingen. Germany - Tel.:.49 7151 509 0 - Fax: 49 7151 509 200
Electronic Digital Thermostat with Defrost Control
for Ventilated Units Working at Low Temperature Ranges
Type Min Max Unit Def
C
00 +199
F
-20
+20 °C/°F 0.0
C
1
15
C
1
15
C
0
100
C
0
1
C
0
1
F
0.1 +19.9 °C/°F
C
-60
r2 °C/°F -50
C
r1
+199 °C/°F 60
dP-parameter) 0=OFF, 1=ON.
flag
0
C
0
+20 °C/°F 3.0
C
0
1
F
0
199 hours
F
-50
+90 °C/°F
F
-50
+90 °C/°F
C
0
15
C
0
15
C
0
15
C
0
15
C
0
100 min
C
0
15 hours
C
0
15 hours
C
0
3
F
0
199 hours
F
-50 +199 °C/°F
F
1
199 min
C
0
1
C
0
199 min
0
1
F
0
15
Parameter
-
22
d8
Alarm delay after defrost and/or if A4 or A5=5,
when door is open
d9
Priority of the defrost over compressor safety (c1, c2, c3)
(0=no,1=yes)
-
4
d/
Defrost sensor reading (d0 = 0 or 1)
-
8
dC
Time selection (0=hours/min,1=min/s) C
-
0
flag
0
A
ALARM PARAMETERS
flag
0
A0
Alarms and fans delta
AL
Low temperature alarm
(with respect to set-point)
2
AH
High temperature alarm
(with respect to set-point)
Ad
Temperature alarm delay
A4
Configuration of the digital input No. 1 C
C
0
A5
Configuration of the digital input No. 2 C
A6
Duty setting in case of external alarm
(0=OFF, 1=ON)
A7
External alarm delay (A4 or A5=2)
F
FAN PARAMETERS
flag
0
F0
Management of fans: 0= fans always ON – specific phases
-
excluded
-
1= thermostatic fans on the basis of the difference between
-
ambient and evaporator temperature,
2= thermostatic fans according to the
evaporator temp.
F1
Starting temperature of the fans:
min
0
Evaporator temperature < (ambient temperature - F1 - A0) = fans are ON
min
0
Evaporator temperature > (ambient temp. - F1) = fans are OFF
min
0
min
0
Evaporator temperature < (Set-point + F1 - A0) = fans are ON
Evaporator temperature > (Set-point + F1)= fans are OFF
0
4
F2
STOP fans when compressor idle
2
(0=no, 1=yes)
F3
Fans off during defrost (0=no,1=yes)
Fd
Stop after dripping
flag
0
H
OTHER SELECTIONS
8
H0
Serial address not available
4
H1
Relay 4: alarm/aux (0=aux,1=alarm)
H2
0=buttons disabled; 2=IR & buttons disabled;
30
3=IR remote control disabled
flag
0
H3
Password for IR remote control
H4
1=buzzer disabled
0
Note: Concerning the indicated parameters, it is recommended to check, before
flag
1
installing, if the factory value is suitable for the required use.
min
2
EA, EB, EE: data acquisition failure; controller RESET
Set again the default parameters value:
• switch-OFF the control;
• press the PRG button while switching on the control;
• "-c-" is displayed;
• after few seconds the RESET phase begins and it is possible to change
the parameters; (*)
• if EE persists, press the
(*) Re-setting the default values causes the loss of the modifications
relative to the working parameters.
Ed BLINKS: timeout defrost
• Verify the dt, dP and d4 parameters
• Verify defrost efficient
dF BLINKS: defrost currently ON
• It is not an alarm signal. It simply indicates a defrost cycle in progress.
It appears only if the parameter d6=0.
N.B. When cleaning the display use damp cloth and neutral detergent.
ALCO reserves the right to modify the contents of its products without prior notice.
EC1-040
Type Min Max Unit Def
F
0
15 hours
C
0
1
F
-
-
0
1
C
0.1
+20 °C/°F 0.2
F
0
+199 °C/°F
F
0
+199 °C/°F
C
0
199 min 120
0
7
0
7
C
0
100 min
C
0
199 min
(see F2, F3 and Fd parameters)
C
0
2
Case A F0=1:
Case B F0=2:
F
0
+20 °C/°F
C
0
1
C
0
1
F
0
15
C
0
15
C
0
1
C
0
3
C
00
199
C
0
1
button until the error indication disappears.