5.6. Check pressures & adjust if necessary.
5.7. If flame has come to the torch, follow instructions for gas control.
6.
INSTRUCTIONS FOR USE
6.1. Follow instructions of chapter 2 (CONNECTING THE TORCH) & instructions of CS-300
shank.
CS-300-CE-1 HEATING ATTACHMENT WITH ACETYLENE
Art Nr.
230273.1
6.2. Slowly open gas cylinders.
6.3. Open one turn of the oxygen valve on the shank. Adjust on the oxygen regulator the
recommended working pressure for the attachment that has been mounted (see table).
Check if gas flows normally & close valve on the shank.
6.4. Follow same procedure for the fuel gas valve of the shank & fuel gas regulator.
6.5. To light the torch, open the oxygen valve & then the fuel gas valve, light the flame prefera-
bly with special gas lighter.
6.6. Adjust with both valves on the shank until obtaining the suitable flame. Check on regula-
tors that preset pressures remain the same. On the contrary, adjust till the recommended
values are reached.
7.
MAINTENANCE
7.1. Clean the torch at regular intervals to avoid presence of grease or dirtiness. When ne-
cessary, clean the holes of the cutting nozzles with the cleaning needles supplied (art nr.
230520.3).
7.2. Check that flexible hoses are in good condition & remove parts that are damaged.
7.3. Check that connections are secured with hose clamps that cannot hurt the hose by exces-
sive pressure (to avoid cutting of the hose).
7.4. Replace non return valves when gas flow is reduced & every time a gas back-flowing has
happened.
7.5. Check gas escapes with leak detecting fluid (NEVER WITH FLAME); change immediately
the damaged component.
7.6. When necessary, change head & injector; check tightness.
8.
SPARE PARTS
PRAXAIR SOLDADURA, S.L. - C/Orense, 11 - 28020 MADRID - SPAIN
PH NR. 91 453 31 33
Oxygen
bar
3-4
7/8
Acetylen
bar
0,5
EN