Descargar Imprimir esta página

Migatronic OMEGA 3 YARD 300 Manual Del Usaurio página 14

Ocultar thumbs Ver también para OMEGA 3 YARD 300:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
PULSE / SYNERGIC control panels
PULSE control panel
A
2
3
1A
1
14
15
Left control knob
1
Setting of welding current, wire feed speed or
material dimension:
Press the
key briefly (1A):
Press the key briefly to switch between display of welding
current, wire feed speed and material dimension.
Press and hold the
Press and hold the key to select welding programs. A
"P" and a figure will be shown in the display. The figure
indicates a specific welding program. A welding program
includes wire type, wire dimension and gas type. The
active welding program is marked with "."
Reset to factory settings in selected program
Factory settings can be reloaded for the active welding
program. When the active program is displayed, press and
hold the
-key to exit the program list.
14
10
6
V
7
11
V
5
8
12
9
13
4A
4
61111426
PULSE III
16
17
18
key (1A):
SYNERGIC control panel
10
11
A
2
12
3
13
1A
1
SYNERGIC III
14
15
16
Display for current
2
Wire feed speed
Material dimension
When the machine is not welding, the
set current/wire feed speed/material dimension in
MIG/MAG is displayed or in MMA the set current.
During welding the measured current is displayed.
Material thickness (synergic MIG)
3
The function helps adjusting the current according
to material thickness (in mm). When selecting
material thickness an automatically setting of current
is calculated. Thereafter, the current can be further
adjusted.
Selected material thickness typical for the selected
material can be found under this function. The material
thicknesses are normally stated in rolls.
The material thickness function can be seen as a good
starting point in the selection of correct current and
voltage. A trimming of these parameters will be required
in almost every welding task in order to obtain the most
optimum result.
Right control knob
4
Setting of trim voltage, voltage or arc adjust.
Press the
key briefly (4A):
Press the key briefly to switch between display of trim
voltage, voltage, arc adjust and seam average (welding
current/voltage).
Press and hold the key
Press and hold the key to select setting of secondary
parameters. Turn the left control knob to select parameter
and turn the right control knob to set values for the
selected parameter.
If the
-key is activated, Duo PLUS
(
and
6
V
7
V
5
8
9
4A
4
61111426
18
(4A):
parameters
TM
) will be adjustable.

Publicidad