Datos Técnicos - Daikin Altherma 3 GEO EGSAH06DA9W Manual De Instalación

Ocultar thumbs Ver también para Altherma 3 GEO EGSAH06DA9W:
Tabla de contenido

Publicidad

9 Datos técnicos
S2S
# Entrada de pulso del medidor eléctrico 1
S3S
# Entrada de pulso del medidor eléctrico 2
S6S~S9S
# Entradas digitales de limitación energética
SS1 (A4P)
* Interruptor selector
TR1, TR2
Transformador de suministro eléctrico
X*A
Conector
X*M
Regleta de terminales
X*Y
Conector
Z*C
Filtro de ruido (núcleo de ferrita)
*
Opcional
#
Suministro independiente
Traducción de texto de diagrama de cableado
Inglés
(1) Main power connection
For preferential kWh rate power
supply
Normal kWh rate power supply
Only for preferential kWh rate
power supply with separate
normal kWh rate power supply
Only for preferential kWh rate
power supply without separate
normal kWh rate power supply
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
(2) Power supply BUH
BLK
BLU
BRN
GRY
Only for combined 1F BUH/
compressor power supply (3/6
kW)
Only for combined 3F BUH/
compressor power supply (6/9
kW)
Only for dual cable power supply Solo para suministro eléctrico de
Only for single cable power
supply
Only for split 1F BUH/1F
compressor power supply (3/6
kW)
Only for split 3F BUH/1F
compressor power supply (6/9
kW)
SWB
YLW/GRN
(3) User interface
Only for remote user interface
SWB
(4) Drain pump
Manual de instalación
38
Traducción
(1) Conexión de alimentación
principal
Para suministro eléctrico de flujo
de kWh preferente
Suministro eléctrico de flujo de
kWh normal
Solo para suministro eléctrico a
flujo de kWh preferente con
suministro eléctrico a flujo de
kWh normal separado
Solo para suministro eléctrico a
flujo de kWh preferente sin
suministro eléctrico a flujo de
kWh normal separado
Contacto de suministro eléctrico
de flujo de kWh preferente:
detección de 16 V CC (tensión
suministrada por PCB)
Caja de interruptores
(2) Suministro eléctrico de la
resistencia de reserva
Negro
Azul
Marrón
Gris
Solo para suministro eléctrico
combinado de resistencia de
reserva/compresor 1F (3/6 kW)
Solo para suministro eléctrico
combinado de resistencia de
reserva/compresor 3F (6/9 kW)
cable doble
Solo para suministro eléctrico de
cable único
Solo para suministro eléctrico
dividido de resistencia de reserva
1F/compresor 1F (3/6 kW)
Solo para suministro eléctrico
dividido de resistencia de reserva
3F/compresor 1F (6/9 kW)
Caja de interruptores
Amarillo/verde
(3) Interfaz de usuario
Solo para interfaz de usuario
remota
Caja de interruptores
(4) Bomba de drenaje
Inglés
SWB
(5) Ext. indoor ambient thermistor (5) Termistor ambiente interior
SWB
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Continuous
DHW pump
DHW pump output
Electrical meters
For safety thermostat
Inrush
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
(7) Option PCBs
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: ext. heat source output,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Traducción
Caja de interruptores
externo
Caja de interruptores
(6) Opciones de suministro
independiente
Detección de pulsos CC 12 V
(tensión suministrada por la
PCB)
230 V CA suministrados por PCB
Corriente continua
Bomba de agua caliente sanitaria
Salida de bomba de agua
caliente sanitaria
Medidores eléctricos
Para termostato de seguridad
Corriente de irrupción
Carga máxima
Normalmente cerrado
Normalmente abierto
Contacto de termostato de
seguridad: detección de 16 V CC
(tensión suministrada por PCB)
Válvula de aislamiento
Caja de interruptores
(7) PCB de opciones
Salida de alarma
Conmutación a fuente de calor
externa
Carga máxima
Carga mínima
Solo para la opción de PCB de
demanda
Solo para opción PCB E/S digital
Opciones: salida de fuente de
calor externa, salida de alarma
Opciones: salida de
ENCENDIDO/APAGADO
Entradas digitales de limitación
energética: detección 12 V CC /
12 mA (tensión suministrada por
PCB)
Salida de ENCENDIDO/
APAGADO de la calefacción/
refrigeración de habitaciones
Caja de interruptores
(8) Termostatos de
ENCENDIDO/APAGADO externo
y convector de bomba de calor
Temperatura del agua de
impulsión en la zona adicional
Temperatura del agua de
impulsión de la zona principal
Solo para sensor externo (suelo
o ambiente)
Solo para convector de la bomba
de calor
Solo para termostato de
ENCENDIDO/APAGADO con
cable
EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569811-1 – 2019.02

Publicidad

Tabla de contenido
loading

Tabla de contenido