Parameter name

Polarity
DI1 input polarity
nc=normally closed, no=normally open
keyboard lock enable
Readouts
Controller status
S0=cooling ON/Heating ON,
S2=wait for compressor ON time to elapse,
S3=wait for compressor OFF time to elapse-restart
time, S4=drip OFF delay after defrost,
S10=cooling stopped by MainSwitch=OFF,
S11=cooling stopped by thermostat/heating OFF,
S14=defrosting state,
S15=fan delay state after defrost,
S17=door open (DI input), S20=emergency cooling,
S25=manual control of outputs,
S30=continous cycle/Pull-down
S32=delay of outputs at power up
Air temperature (Sair)
Read the present regulation reference
DI1 input
Status of night operation
Condenser temperature (Sc)
Compressor relay status
Firmware version readout
| 18
Code
Min
Max
Unit
P--
P73
nc
no
P76
no
yES
u--
u00
S0
S32
u01
-100.0
200.0
C/F
u02
-100.0
200.0
C/F
u10
oFF
on
u13
oFF
on
U09
-100.0
200.0
C/F
u58
oFF
on
u80
000
999