GB INSTALLATION
INSTRUCTIONS
ACCESS CONTROL FOR
TM SERIES ENTRY PANEL
Two different configurations can be
created, depending on the degree of
security required for the access con-
trol.
The standard minimum level can be
created using the MNA/102LR, since
the device control comes about
through the contacts of the 2 relays
with which it is fitted.
A greater degree of system security
requires the addition of one or more
IOD/100LR actuators which, connec-
ted to the MNA/102LR module via the
bus, enable control to be removed
from the actual devices themselves,
thus preventing them from being for-
ced in the event the MNA/102LR
should be tampered with.
MNA/102LR ACCESS
CONTROL MODULE
The unit is a keypad with a backlit
cover (fig. 5) suitable for TM series
entry panels.
It is equipped with following controls
and warnings indicators, figure 5:
0÷9
buttons for inputtings codes
and programming procedure
button for an alarm or a bell
activation
#
relays block button in the acti-
ve mode
LED
three LEDs indicating module
mode and functions progress.
Functions
a) Up to 100 user codes can be sto-
red. The codes can be made up of 3
or 4 or 5 digits with values in the
range 1÷65535.
Each code can be associated with
one of the 2 service relays.
b) The module is fitted with 2 service
relays with the following functional
features:
- programmable activation time for
each relay;
- monostable or bistable operating
mode for each relay;
- possibility, in the monostable ope-
rating mode, of blocking the relays in
the active state by pressing key #
before the activation time is up;
- output state normally open or clo-
sed depending on the connection to
the relays' NO or NC contacts;
- relay 2 can be associated with an
alarm-activation service or a bell-acti-
vation service.
The alarm and the bell are mutually
exclusive.
The activation of the alarm, when
enabled, is done by the user by pre-
ceding his code with the key
The bell, when enabled, is activated
by using key
.
In both cases, no user codes should
be associated with relay 2 if you want
to avoid the entry of said codes cau-
sing the activation of that relay.
c) Acoustic signals are generated to
confirm the pressing of a key, the
various programming phases, etc. in
the following ways:
- confirmation of key being pressed =
short signal;
- correct operation = long signal;
- error = three short signals.
d) The mode of the module and the
functions in progress are indicated
by LEDs (fig. 5):
4
- green LED (A in fig. 5)
always lit = in service mode,
flashing = in programming mode;
- red LED (B in fig. 5)
(to be defined) = auxiliary services;
- yellow LED (C in fig. 5)
pulse = acknowledgement of servi-
ce activation.
e) The keypad can be blocked and
released by using a specific code.
f) The codes and operating modes
can be programmed using the key-
pad.
g) The keypad is blocked for a pro-
grammable time if - after 20 digits
have been pressed - no valid code
has been entered.
h) There is an electric contact input
with the function of activating the ser-
vice relating to relay 1.
i) The default configuration values
can be reset by using the RESET
function.
The stored user codes and the pro-
grammed number of digits are main-
tained.
Functions with module
MNA/102LR and actuator
IOD/100LR
With the aid of actuator IOD/100LR,
the following functions can be added
to the standard functions:
a) The relay 1 and relay 2 functions
can
be
removed
MNA/102LR
module
IOD/100LR actuator.
b) An additional relay (relay 3) is avai-
lable on the IOD/100LR actuator with
which user codes can be associated.
c) The 3 relays of the IOD/100LR
actuator have 250V ~ 5(2) A swit-
ching contacts.
d) A number of MNA/102LR and
IOD/100LR can be connected to the
bus (max. 32).
PROGRAMMING
Default
values
with
MNA/102LR module is supplied:
PROGRAMMING CODE: 12345 (5
digits);
RESET CODE: obtained from the
identification code (ask the installer
or BPT technical service for advice);
USER CODE on relay 1: 2580;
USER CODE on relay 2: 3690;
ACTIVATION TIME for the service
relays: 5s;
ACTIVATION TIME for the service
relays: monostable;
NUMBER OF DIGITS for the user
codes: 4;
Keypad BLOCKING TIME: 10s;
BELL LENGTH: 3s;
ALARM CODE: disabled;
KEYPAD: enabled;
INPUT FOR CONTACT: enabled;
BELL: disabled.
.
PROGRAMMING PROCEDURE
In order to enter the programming
mode, keys 1 and 7 must be pressed
simultaneously, and then the PRO-
GRAMMING CODE entered (the
green LED flashes).
The FUNCTION CODE must then be
entered in order to select the type of
function required.
Once the data required has been
inputted, another type of function can
be selected, or the programming
mode terminated by entering 99 (in
this case the green LED stops fla-
shing).
Once the data requested by the func-
tion have been inputted, a long acou-
stic signal sounds if the operation is
correct, or three short signals sound
if it is incorrect.
Modifying the programming code
(function 01)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 01.
3) Enter the new PROGRAMMING
CODE (5 digits).
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Adding a user code (function 02)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 02.
3) Enter the SERVICE/RELAY requi-
red (1 or 2 or 3).
4) Enter the USER CODE (3 or 4 or 5
digits).
5) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Erasing a user code (function 03)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 03.
from
the
3) Enter the USER CODE (3 or 4 or 5
onto
the
digits).
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Erasing all user codes (function 04)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 04.
3) Enter the USER CANCELLATION
CODE 0.
4) Proceed, starting from point 2), in
which
the
order to start another function, or
enter 99 to end the programming.
Setting the service relay
activation time (function 05)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 05.
3) Enter the SERVICE required (1 or
2 or 3).
4) Enter the ACTIVATION TIME 01÷65 s.
5) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Setting the keypad blocking time
(function 06)
(resulting from non-existent codes
being repeatedly entered)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 06.
3) Enter the BLOCKING TIME 01÷65 s.
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Changing the number of digits
of the user code (function 07)
(all the codes have the same number
of digits)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 07
3) Enter the NUMBER OF DIGITS (3
or 4 or 5).
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Setting the relay monostable
or bistable mode (function 08)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 08.
3) Enter the SERVICE/RELAY requi-
red (1 or 2 or 3).
4) Enter the TYPE OF ACTIVATION
0 = BISTABLE
1 = MONOSTABLE.
5) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Enabling/disabling the alarm
(function 09)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 09.
3) Enter the mode
0 = DISABLED
1 = ENABLED.
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Enabling/disabling the bell
(function 10)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 10.
3) Enter the mode
0 = DISABLED
1 = ENABLED.
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Enabling/disabling the entrance I1
(function 11)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 11.
3) Enter the new ENTRANCE mode
0 = DISABLED
1 = ENABLED.
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Enabling/disabling the keypad
(function 12)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 12.
3) Enter the new KEYPAD mode
0 = DISABLED
1 = ENABLED.
4) Proceed, starting from point 2), in
order to start another function, or
enter 99 to end the programming.
Resetting the alarm (function 13)
1) Enter the PROGRAMMING CODE
(if you are not already in the pro-
gramming mode).
2) Enter the FUNCTION CODE 13.
3) Proceed, starting from point 2), in
order to start another function, or enter
99 to end the programming.
Changing the safety code
(function 14)
1) Enter the PROGRAMMING CODE
(if not already in the programming
mode).
2) Enter the FUNCTION CODE 14.
3) Enter the SAFETY CODE currently

Publicidad