Recommended Spare Parts - Ecolab Foamatic Mainstation S-version Guía De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.1 The unit does not start up 
1  Is voltage available? 
2  Is pressure water available? 
3  Defect fuse? 
4  No connection between controller 
and control panel? 
5   
 
 
 
 
5.2 Unsatisfying foam quality 
1  Unsuitable detergent? 
2  Concentration of detergent too low? Adjust the concentration on the dosing valve. 
3  Is the air pressure too high or low? 
4  Stemmer dyserne i zonerne overens 
med volumen af injektoren? 
5  Is the suction filter clogged up? 
6  Is the volume of water and pressure 
in the unit sufficient? 
7  Is the injector clogged up? 
8   
 
 
6.Recommended Spareparts 
 
Spare parts for standard Foamatic unit with one detergent. 
 
Item no 
0664034 
0664080 
0664073 
637000 
939904 
 
 
 
 
Secure voltage supply to the unit. 
Check the booster unit. Is the main supply open? 
Exchange the fuse. 
Check cabel connection between controller and control 
panel. 
Contact service technician. 
Change to suitable detergent.
Adjust the air pressure on the regulator. 
Exchange or clean nozzles in the zone. 
Clean filter 
Secure correct water supply and water pressure. 
Disassemble injector and clean nozzle. 
Contact service technician. 
Description 
Non return valve, air
Non return valv, rinse 
Non return valve, detergent 
Air regulator 
O‐Ring union 
 
13 
Quantity 
1

Publicidad

Tabla de contenido
loading