5.1 The unit does not start up
1 Is voltage available?
2 Is pressure water available?
3 Defect fuse?
4 No connection between controller
and control panel?
5
5.2 Unsatisfying foam quality
1 Unsuitable detergent?
2 Concentration of detergent too low? Adjust the concentration on the dosing valve.
3 Is the air pressure too high or low?
4 Stemmer dyserne i zonerne overens
med volumen af injektoren?
5 Is the suction filter clogged up?
6 Is the volume of water and pressure
in the unit sufficient?
7 Is the injector clogged up?
8
6.Recommended Spareparts
Spare parts for standard Foamatic unit with one detergent.
Item no
0664034
0664080
0664073
637000
939904
Secure voltage supply to the unit.
Check the booster unit. Is the main supply open?
Exchange the fuse.
Check cabel connection between controller and control
panel.
Contact service technician.
Change to suitable detergent.
Adjust the air pressure on the regulator.
Exchange or clean nozzles in the zone.
Clean filter
Secure correct water supply and water pressure.
Disassemble injector and clean nozzle.
Contact service technician.
Description
Non return valve, air
Non return valv, rinse
Non return valve, detergent
Air regulator
O‐Ring union
13
Quantity
1
1
1
1
1