Preventative Maintenance - Vollrath JT1 Manual Para Operadores

Tostadores con correa transportadora para panes y bollos - 250 a 500 rebanadas por hora
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PREVENTATIVE MAINTENANCE

Contact an authorized service agent for a professional cleaning of the components.
TROUBLESHOOTING
Problem
Toaster does not heat and the
conveyor belt does not move.
Toaster heats and the conveyor belt
does not move.
Top or bottom heat tubes do not
heat.
Toaster repeatedly overheats.
The fan is not running.
Conveyor Bread and Bun Toasters - 250-500 Slices Per Hour* Operator's Manual
Might be Caused By
Toaster is not plugged in.
Power knob setting is incorrect.
The wall breaker may be tripped.
The reset may be tripped.
There may be a problem with the motor/
speed control or drive chain.
One or more elements may have burned
out.
The crumb tray may not be installed.
The fan may be dirty.
There may be a problem with the fan.
There may be a problem with the fan.
Course of Action
Plug in the toaster.
Rotate the power knob to the ON (|) position.
1. Inspect for tripped breaker.
2. Reset the breaker.
3. If the breaker was not tripped, inspect the toasting chamber for
broken heater elements.
4. For broken elements, contact Vollrath Technical Services.
Look under the toaster to see if an object is preventing the fan
blades from turning.
1. Rotate the power knob to the OFF (O) position.
2. Unplug the toaster.
3. Wait 30 minutes for the toaster to cool.
4. Remove the object.
5. Plug in the toaster.
6. Rotate the power knob to the ON (|) position.
7. Press the reset button, located below the back panel. You
should hear and feel the button reset. The toaster should start to
operate.
8. If the problem persists call Vollrath Technical Services.
Inspect the fan blades to see if they are dirty.
1. Rotate the power knob to the OFF (O) position.
2. Unplug the toaster.
3. Wait 30 minutes for the toaster cool.
4. Clean the fan blades.
5. Plug in the toaster.
6. Rotate the power knob to the ON (|) position.
7. Press the reset button.
8. If the problem persists call Vollrath Technical Services.
Contact Vollrath Technical Services.
Contact Vollrath Technical Services.
Verify the crumb tray is installed.
Verify the fan blades are clean. See instructions above for
inspecting and cleaning the fan blades.
Contact Vollrath Technical Services.
Contact Vollrath Technical Services.