Temperature control energy-saving features
• When the difference between acutal detected temperature and set temperature are
within 3°C (for example, set 18°C and detected 16°C -18°C), heating power is
750 W.
• When the difference between acutal detected temperature and set temperature
exceeds 3°C (for example, set 18°C, detected as 15°C or below), heating power
is 1500 W.
• When the actual detected temperature is 1°C higher than the set temperature, the
heating will be off (for example, set to 27°C, the actual test is 28°C), the fan will
stop working after 10 seconds.
• Press the power off button on the control panel, the temperature control function will
record the last setting when power on again.
Open Window function (additional hidden functions)
In the thermostat control heating mode, when the ambient temperature drops over 5°C
within 10 minutes, the buzzer will make a „beep" sound three times and the digital
display will show [E8]. This means there is window open or there may exist some cooling
items opened, at the same time the temperature control turns the heating off.
Closing the window or cooling items the ambient temperature will not fall down again
and the display [E8] disappear. [E8] characters will not disappear if you turn off the
heating by the control panel or remote control, even when window is not closed. You
will need to turn the appliance off at the wall and unplug from the power supply.