Descargar Imprimir esta página

Safety Precautions; System Operation - golmar Digital Plus Nexa Guía Rápida

Publicidad

Idiomas disponibles

Idiomas disponibles

VIDEO SYSTEM PLUS NEXA - BUILDING

SAFETY PRECAUTIONS

- Install or modify the equipment, without the power connected.
- The installation and handling of these equipments must be performed by authorised personnel.
- The entire installation must be at least
40 cm.
- With power supply:
w Do not use excessive force when tightening the connector screws.
w Install the power supply in a dry and protected place without risk of drip or water projections.
wAvoid to place it near to heating sources, in dusty locations or smoky enviroments.
wDo not block ventilation holes of the unit so that air can circulate freely.
wTo avoid damage, the power supply has to be firmly fixed.
wTo avoid an electrical shock, neither remove the protection cover nor handle the connected wire
in the terminals.
( )
( )
CHARACTERISTICS
3
*
- Audio and video door entry system with simplified installation:
w Audio door entry system with 4 common wires installation.
w V
ideo
door entry system with 3 common wires plus coaxial cable installation.
w V
ideo
door entry system with 4 common wires plus twisted pair installation
- Sound module with two operating modes (EL500 or EL501).
- Unlimited number of door panels (access) being not necessary the use of switching units.
- Up to 120 monitors / telephones per installation or backbone.
- General door panel (EL501 mode): Up to 120 monitors / telephones , distributed in max. 120 buildings.
- Acoustic busy channel and call acknowledgment signals.
- Visual indications on the door panel for people with impaired hearing: (call and communication
process, door release and busy system).
- EL560 module for video installations with twisted pair cable, integrated in sound module.

SYSTEM OPERATION

To make a call the visitor should press the push button corresponding to the apartment he
O
wishes to contact. An acoustic tone will be heard confirming the call is in progress once the push
button has been pressed
and the door panel led
received at the monitor (telephone) in the dwelling. During the call the visitor can correct his call
by pressing a push button corresponding to a different apartment, in which case the original call
is cancelled.
In systems with several accesses doors, the other(s) door panel(s) will be automatically
O
disconnected:
If a visitor tries to call from other door panel an acoustic tone will be heard and the door panel
led will be on
confirming the system is busy
General door panel (EL501 mode): If the call is made from the general door panel, the inner
O
door panel of the building called and other possible general door panel will remain
automatically disconnected, if another visitor tries to call from an inner busy door panel an
acoustic tone will be heard
and the door panel led
from another general door panel, an acoustic tone will be
and
the general door panel led
will blink for 3 seconds
buildings will remain free to be used.
General door panel (EL501 mode): In the case that the call is made from an inner door panel,
O
the rest of inner door panels will remain free to be used. From general door panels only will be
able to make calls to the inner buildings whose door panels are not in use, if the visitor tries to
make a call to a busy inner door panel, an acoustic tone will be heard confirming the system is
busy and the
general door panel
led
The call tone will be reproduced on the monitor during 3 seconds: after this time the picture will
O
appear on the master monitor without the visitor being aware of this. To see the picture in a
slave monitor press the
push button, dissapearing the picture on the other monitor. If the call
is not answered in 45 seconds,
the door panel led
To establish communication pick up the monitor (telephone) handset
O
The communication will last for one and a half minutes or until the handset is replaced. Once the
O
communication has finished the
door panel led will turn off and the
To open the door, press the door release push button during call or communication progresses:
O
with one press, the door release operates during 3 seconds. During the lock release activation
an acoustic tone will be heard on the door panel confirming the lock release is activated and the
led will also turn on for 3 seconds.
( ) For more information see manual "T632/PLUS ML (cod. 50121859)".
*
https://doc.golmar.es/search/manual/50121859
away from any
other installation.
.
will turn on
. At this moment the call will be
.
will be on
confirming the system is busy or
heard
confirming the system is busy
. The door panels of the others inner
will blink for 3 seconds
.
will turn off and
the system will be freed.
, door panel led will turn on
system will be freed.
2
VIDEO SYSTEM PLUS NEXA - BUILDING
DOOR PANEL INSTALLATION
( )
*
1650
1450
The push buttons module EL610D must be configured, to assign a call code to the push
buttons (use the tool that is supplied with the sound module). Make this configuration
with the dip switch placed in the back side of the module.
Depending on the setting selected, the push buttons are assigned to a specific call code.
In case to combine these door panels with coded door panels or porter's exchange, it will
be necessary to known the call code of each push button, as shown in the table below.
Dip1
Dip2 Dip3 Dip4 Dip5 Dip6 Dip7 Dip8
1
On
Off
2
Off
On
3
Off
Off
4
Off
Off
5
Off
Off
6
Off
Off
7
Off
Off
8
On
Off
9
Off
On
10
Off
Off
11
Off
Off
12
Off
Off
13
Off
Off
P1- P10: Push button 1 to push button 10.
(1)
Note:Sound module factory set the code "
,
Important: Select a different configuration option for each module EL610D.
Factory default.
( ) 2
( ) Description and adjustments:
*
- Description of the visual indications on the door panel.
- Description of the door panel led lights (only EL632 Plus module).
- Description of CN8 Bus Nexa connector.
.
- Description of the SW1 and SW2 configuration dip-switch.
- Description of CN3 function connector.
- Adjustment audio volume.
( )
( )
*
3
Operation and programming monitors / telephones.
( )
Installations with monitors/telephones Uno, see "Annex" from manual T632/PLUS ML (cod. 50121859).
3
( ) For more information see manual "T632/PLUS ML (cod. 50121859)".
*
https://doc.golmar.es/search/manual/50121859
Embedding box dimensions:
Door panel
90CS
90C
Model
CE
A90C
CEV90C
1850
W
99
99
H
1 3
4
250
D
40
56
Push buttons module EL-610D
Dip switch
Push buttons code
P1
P2 P3 P4 P5 P6 P7
Off
Off
Off
Off
Off
On
1
2
3
4
5
6
Off
Off
Off
Off
Off
On
11
12
13
14
15
16
On
Off
Off
Off
Off
On
21
22
23
24
25
26
Off
Off
Off
Off
31
32
33
34
35
36
On
On
Off
Off
On
Off
Off
On
41
42
43
44
45
46
Off
Off
Off
On
Off
On
51
52
53
54
55
56
Off
Off
Off
Off
On
On
61
62
63
64
65
66
Off
Off
Off
Off
Off
Off
71
72
73
74
75
76
Off
Off
Off
Off
Off
Off
81
82
83
84
85
86
On
Off
Off
Off
Off
Off
91
92
93
94
95
96
Off
Off
Off
Off
Off
On
101
102
103
104
105
107
Off
Off
On
Off
Off
Off
112
113
114
115
116
117
Off
Off
Off
On
Off
Off
122
123
124
125
126
127
in P1 and "
in P2
106"
132"
3
90
CEV90
99 mm.
328 mm.
56 mm.
( ) 2
P8 P9 P10
(1)
7
8
9
10
( ) 2
17
18
19
20
27
28
29
30
37
38
39
40
47
48
49
50
57
58
59
60
67
68
69
70
77
78
79
80
87
88
89
90
97
98
99
100
108
109
110
111
118
119
120
121
128
129
130
131
.

Publicidad

loading

Este manual también es adecuado para:

50121859