STEP
5
Hang the Filter System Head
1
A
Align the System Head
on the pipes so that the inlet and outlet are in the correct locations. The "in" port on the System Head
should be facing the incoming water supply.
2
Allow the System Head to temporarily hang between the two cut plumbing pipes.
3
Apply plumber's tape or appropriate sealant to the fittings and lines, according to your system configuration.
4
Make all connections and tighten fittings.
NOTE: Keep the Filter System in an upright position.
5
E
Attach the Mounting Bracket
CAUTION
A grounding kit (not included) must be installed on water pipes if they are
used to ground electrical systems, appliances or phones.
GROUNDING KIT (NOT INCLUDED)
STEP
6
Hang the Filter Housing
1
B
Insert the Filter Cartridge
over standpipe in the bottom of the Filter Housing
2
Screw the Filter Housing back onto the System Head and hand-tighten. Using the Filter Housing Wrench
NOTE: Do not over tighten.
WFPF13003B
to the wall using the four 2" Mounting Screws
F
or alternative fasteners (not included).
A
.
D
, tighten 1/4 turn.
5
5
E
IN
A
WATER
FLOW
3
5
E
6
D
A
OUT
TO
HOUSE
G
2
V4.0