3. Connect POL fitting on hose/regulator assembly to propane tank(s).
Turn POL fitting counterclockwise into threads on tank. Tighten firmly.
IMPORTANT: Tighten regulator with vent pointing down. Pointing vent down protects
regulator from weather damage.
4. Open valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check
valve on propane tank will stop gas flow. If this happens, close propane valve and open
again slowly.
5. Check all connections for leaks. Apply mixture of liquid soap and water to gas joints.
Bubbles forming show a leak that must be corrected before using heater.
6. Close propane supply valve.
Review and understand the warnings in the General Safety Information
Section. They are needed to safely operate this heater. Follow all local ordi-
nances or codes when using this heater.

To Start Heater

1. Follow all preparation, ventilation, and safety information.
2. Locate heater on stable and level surface. Make sure strong drafts do not blow into front
or rear of heater. Do not use in areas directly exposed to water spray, rain, and/or dripping
water.
3. Open valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve
on propane tank will stop gas flow. If this happens, close propane valve and open again
slowly.