Safescan TA-800 Serie Manual página 8

Ocultar thumbs Ver también para TA-800 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
5.1
Shutdown
5.2
PowerOn
5.3
Sleep
5.4
Idle
5.5
Idle Min
5.6
Bell Delay
5.7
Scheduled Bell
5.8
Sch. State
5.9
Lock Power
5.10
Baudrate
5.11
Dev Num
5.12
DHCP
5.13
Net Speed
5.14
IP Addr
5.15
NetMask
5.16
Gateway
5.17
Ethernet
5.18
RS232
5.19
RS485
5.20
USB
5.21
COMM Key
5.22
Enable Proxy
5.23
Proxy server
5.24
Proxy port
5.25
Alm SuperLog
5.26
Alm AttLog
5.27
ReCheck Min
5.28
Run All Test
5.29
FLASH Test
5.30
LCD Test
5.31
FP Reader
5.32
Key Test
5.33
RTC Test
6.1
DwnLoad AttLog
6.2
DwnLoad User
6.3
Upload User
6.4
Download SMS
6.5
Upload SMS
08
Time to shut down of the device automatically
Time to turn on the device automatically
Time to enter the sleep-mode of the device, press any key to awake it
Choose between Sleep or Shutdown
Time period when the device is not used, after which the device goes into Sleep or Shutdown mode
(as defined in previous command)
Time for the bell to ring
Schedule at what time the bell starts ringing (maximum 50 different times)
Schedule at what time the device is automatically set on Check-In, Check-Out, Overtime-In, Overtime-Out
When set on "Y" the on/off key at the bottom left is switched off
Baudrate of the product
Number of the device (in case more TA's are used in a network)
Dynamic Host Configuration Protocol
Net speed of the device
IP address of the device
Netmask of the device
Gateway of the device
Device can be connected to a network via TCP/IP if set on Y
Not applicable
Not applicable
Device can be connected to a USB stick if set on Y
If set on "0" not active, if set on a pin code the device can only be accessed via TCP/IP if the correct
pin code is set in the TA software5.21
Enable proxy (Y) or disable proxy (N)
Enter the IP address of the proxy server
Input the port of the proxy server
When the supervisor log reaches the value you set, the system will show a message to notice the logs will be full
When the attendance log reaches the value you set, the system will show a message to notice the
logs will be full
The interval in minutes between users are allowed to make a second record (to save memory space)
All available tests will be carried out to check if the device is OK
Test the memory
Test the LCD screen
Test the fingerprint reader
Test the keys of the keypad
Test the Real-time clock of the device
Download attendance logs from the device to a USB stick
Download user information from the device to a USB stick
Download user information from a USB stick to the device
Not applicable
Not applicable