Notice to installing contractor: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
433047
412082
420816
433152
451558
451549
*Effluent systems should specify that pumps should not handle solids exceeding three fourths inch (3/4") in order to prevent large solids from entering leeching fields, mound systems
and etc. Where codes permit, sewage pumps can be used for effluent systems. Nonautomatic pump(s) with external level control recommended for septic tank effluent applications.
PRE INSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
Do Not remove the test plugs in the cover nor the motor housing.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle or control box
must be installed in accordance with the governing codes. Never remove ground
pin from plug.
2. Make certain that the ground fault interrupter protected receptacle or control box is
within the reach of the pump's power supply cord. DO NOT USE AN EXTENSION
CORD. Extension cords that are too long or too light do not deliver sufficient voltage
to the pump motor, and they could present a safety hazard if the insulation were to
become damaged or the connection end were to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit breakers
of proper capacity. A separate branch circuit is recommended, sized according to the
National Electric Code for the current shown on the pump name plate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked for
ground using a circuit analyzer which will indicate if the power, neutral and ground wires
are correctly connected to your outlet. If they are not, call a qualified licensed electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. If pump is wired direct, de-energize the circuit at
the control box. Wear insulated protective shoes and do not stand in water. Pumps
equipped with a 3-prong ground plug are designed to help protect against electrical
shock. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN.
6. Installation and servicing of the pump, electrical circuits and hardware should only be
performed by a qualified licensed electrician.
7. Risk of electrical shock. Do not remove power supply cord and strain relief or connect
conduit directly to the pump. If the supply cable is damaged, it must be replaced by
the Manufacturer or an authorized Zoeller Service Station to avoid a hazard.
8. Pump contains oil which becomes pressurized and hot when operating. Allow 2½
hours after disconnecting before attempting service.
9. Pump is not intended for potable water due to possible contamination by oil contained
in the pump.
10. Risk of electric shock. These pumps have not been investigated for use in swimming
pools and marine areas.
11. Prop65 Warning for California residents: Cancer and Reproductive Harm- www.
P65warnings.ca.gov.
INSTALLATION INSTRUCTIONS
SUBMERSIBLE SUMP PUMPS
DEWATERING AND SEWAGE
MODELS
3SDPH-L
3SD-L
3SPH-L
3SP-L
3SEH-L
3SE-L
5SPH-L
5SP-L
5SDPH-L
5SDP-L
4EP
4EPF
BN4EP
40EC
40ECF
S1137
F1137
S1098
F1098
S1057
200ECF
ECP SERIES
95 N. Oak St. • Kendallville, IN 46755 • 1-800-345-9422
© All rights reserved.
Dewatering
Effluent
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
1. Check to be sure your power source is capable of handling the voltage requirements
of the motor, as indicated on the pump name plate.
2. The installation of variable level float switches is the responsibility of the installing
party, and care should be taken that the tethered float switch will not hang up on
the pump apparatus or pit peculiarities and is secured so that the pump will shut
off. It is recommended to use rigid pipe and fittings and the pit be 18" or larger in
diameter.
3. Vent hole. It is necessary that all submersible sump, effluent, and sewage pumps
capable of handling various sizes of solid waste be of the bottom intake design to
reduce clogging and seal failures. If a check valve is incorporated in the installation,
a 3/16" vent hole must be drilled in the discharge pipe below the check valve and pit
cover to purge the unit of trapped air. Vent hole should be checked periodically for
clogging. The vent hole on a High Head application may cause too much turbulence.
If you choose not to drill a vent hole, be sure the pump case and impeller is covered
with liquid before connecting the pipe to the check valve. NOTE: THE HOLE MUST
BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY. Water stream
will be visible when pump is operating.
4. Pump should be checked frequently for debris and/or build up which may interfere
with the float "on" or "off" position. Repair and service should be performed by an
Authorized Zoeller Service Station only.
5. Maximum operating temperature for standard model pumps must not exceed
130 °F (54 °C).
6. Do not operate a pump in an application where the Total Dynamic Head is less than
the minimum Total Dynamic Head listed on the Pump Performance Curves.
7. For health reasons, do not unplug, turn off, or disable pump and use pump tank
system as a way to fill up a sink or laundry tray, etc.
8. Pumps must be installed in accordance with the National Electrical Code and all
applicable local codes and ordinances. Pumps are not to be installed in locations
classified as hazardous in accordance with National Electric Code, ANSI, NFPA 70.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL
standard UL778. CSA certified pumps are certified to CSA standard C22.2 No. 108.
FW0013
0119
Supersedes
0214
DATE
INSTALLED:
MODEL
NUMBER:
Sewage
X
X
X
X

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Flint & Walling 3SDPH-L

  • Página 1 Consult factory 0214 SUBMERSIBLE SUMP PUMPS regarding discrepancies or inconsistencies. DATE INSTALLED: DEWATERING AND SEWAGE MODEL NUMBER: MODELS Dewatering Effluent Sewage 3SDPH-L 3SD-L 433047 3SPH-L 3SP-L 412082 3SEH-L 3SE-L 420816 5SPH-L 5SP-L 5SDPH-L 5SDP-L 433152 4EPF...
  • Página 2 Pump should be checked frequently for debris and/or build FOR YOUR PROTECTION, ALWAYS DISCONNECT CAUTION PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single up which may interfere with the float “on” or “off” position. Repair and service should be performed by an Authorized Service Station only. phase pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock.
  • Página 3 RECOMMENDED INSTALLATION FOR ALL APPLICATIONS 1. Electrical wiring and protection must be in accordance with National 10. Gate Valve or Ball Valve to be supplied by installer and installed Electrical Code and any other applicable state and local electrical according to any and all codes. requirements.
  • Página 4 SINGLE PHASE WIRING INSTRUCTIONS FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock. DO NOT UNDER ANY CIRCUM- STANCES REMOVE THE GROUND PIN.
  • Página 5: Modelos Recomendados

    DE INSTALACIÓN cación. Se debe consultar a la fábrica cualquier discrepancia o inconsistencia que existiera. NÚMERO DE MODELO: Modelos recomendados MODELOS SUMIDERO/ACHIQUE EFLUENTES AGUAS CLOACALES 3SDPH-L 3SD-L 433047 3SPH-L 3SP-L 412082 3SEH-L 3SE-L 420816 5SPH-L...
  • Página 6 Se debe revisar la bomba frecuentemente para asegurarse PARA SU PROTECCIÓN, SIEMPRE DESCO- PRECAUCIÓN ADVERTENCIA de que no hay escombros y/o acumulación que pueda interferir con la posición NECTE LA BOMBA DE LA FUENTE DE ALIMENTACIÓN ELÉCTRICA "on" (encendido) o "off" (apagado) del flotador. La reparación y servicio deberá ANTES DE MANIPULARLA.
  • Página 7: Instalación Recomendada Para Todas Las Aplicaciones

    INSTALACIÓN RECOMENDADA PARA TODAS LAS APLICACIONES 8. La bomba debe estar nivelada y el mecanismo del flotador libre de los lados del 1. El cableado y la protección eléctrica deben estar de acuerdo con el Código estanque antes de encender la bomba. Eléctrico Nacional y todos los otros requisitos eléctricos locales y estatales 9.
  • Página 8: Instrucciones Para El Cableado Monofásico

    INSTRUCCIONES PARA EL CABLEADO MONOFÁSICO PARA SU PROTECCIÓN, SIEMPRE DESCONECTE LA BOMBA DE LA FUENTE DE ALIMENTACIÓN ELÉCTRICA ANTES DE ADVERTENCIA MANIPULARLA. Las bombas monofásicas se suministran con enchufes de 3 patillas con puesta a tierra para ayudar a protegerle contra la posibilidad de choque eléctrico.

Este manual también es adecuado para:

3sd-l3sph-l3sp-l3seh-l3se-l5sph-l ... Mostrar todo

Tabla de contenido