Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Pressure Booster Pumps
Description
Pressure booster pumps increase water pressure from city mains or private water
systems. Applications include providing high water pressure for washing buildings,
dairy walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment,
lawn sprinkling and insecticide spraying.
Single-phase models are equipped with a capacitor start, thermal protected motor.
Three-phase models require separate overload protection.
7.15
Figure 1
Pump Dimensions 60 Hz
HP
GPM
1/3
5
1/3*
5
1/2
5
1/2*
5
3/4
5
3/4
7
3/4*
7
1
10
1-1/2
10
1*
10
1*
10
1*
10
2
19
1-1/2*
19
2*
19
2
27
3
27
2*
27
3
27
2
35
3
35
1-1/2*
35
3*
35
Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755
1.44
"H" INLET
3.25
"C"
"F"
Stage
"C"
8
10.19
8
10.19
12
13.38
14
14.97
16
16.54
12
13.38
14
14.97
14
16.31
16
18.13
20
21.69
22
23.50
23
24.38
14
17.89
20
24.06
22
26.13
11
15.38
14
18.50
17
21.59
17
21.59
6
13.94
8
17.13
8
17.13
14
26.86
flintandwalling.com
5.28
2 & 3HP
1Ø TEFC ONLY
4.88
TEFC ONLY
"J" DISCHARGE
3.88
3.75
6.50
F
TEFC
F&W
1 Phase
19.81
-
20.06
22.04
23.25
23.23
25.34
26.82
26.91
28.77
23.75
25.61
25.84
27.20
27.18
29.16
29.62
31.48
33.18
34.54
34.99
36.35
35.87
37.73
29.88
32.12
36.05
37.41
38.12
40.36
27.37
29.61
30.49
33.85
33.58
35.82
33.74
-
25.93
28.17
29.12
32.48
29.12
30.48
38.85
42.21
1
Unpacking
When unpacking the unit, inspect
carefully for any damage that may
have occurred during transit.
NOTE: Use pump with clear water
only.
9.75
1-1/2 & 2HP 1Ø TEFC
ALL 3HP 1Ø
IL0391B
H
3 Phase
-
.75
-
.75
24.10
.75
25.69
.75
27.51
.75
24.35
.75
25.94
.75
28.02
.75
30.07
.75
33.40
.75
35.21
.75
36.09
.75
30.87
.75
36.00
.75
39.11
.75
28.36
1.00
33.35
1.00
34.57
1.00
-
1.00
26.92
1.00
31.98
1.00
29.07
1.00
41.71
1.00
132934 D
Chart A
J
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Flint & Walling PB0508S031

  • Página 1 Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Página 2 Suction Disch. Max. Pipe Pipe Powder- Press. Stainless Steel Coated Cast Cast Iron Fitted Stage Output - Gallons per Minute Fitted Iron Fitted 60Hz Models PB0508S031 PB0508C031 PB0508A031 10.2 PB0512S051 PB0512C051 PB0512A051 10.0 PB0516S071 PB0516C071 PB0516A071 10.2 PB0712S071 PB0712C071 PB0712A071 14.0 13.4 12.2 10.9...
  • Página 3: Three Phase Motor Data

    Three Phase Motor Data Chart D Three Phase† 60/50 Hz 3450/2850 RPM Capacitor Start Factory Service Factor Motor Locked Rotor Motor Motor Connected Amps Amps Code Letter Voltage Motor 230V 460V 230V 460V Voltage 208-230/460 230V 1.75 19.0 208-230/460 230V 2.25 26.9 13.5...
  • Página 4: Pre-Installation

    General Safety Information Do not insert finger or any object into pump or motor openings. Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. 10. Secure the discharge line before starting the pump. An Replace missing or damaged safety labels.
  • Página 5: Pump Installation

    IMPORTANT: The entire system must No Air Leaks In Pipe Joint Compound Sags Allow Air Pockets No Sags be air and water tight for efficient/ Inlet Pipe Will Damage Plastic proper operation. If Air Flows Installation Water PUMP INSTALLATION Won’t IMPORTANT: Pump is built to handle clear water only;...
  • Página 6 Installation (Continued) Pump used to boost incoming city pressure (automatic operation). A pressure gauge installed in Street Supply the inlet pipe close to the inlet Gate/Ball port, (See Figure 6) will show if Main Power Box Union Check Valve Valve enough water is being supplied (Normally to the pump.
  • Página 7 Installation (Continued) Pump used to boost incoming pressure from a wall hydrant (manual operation). Hose Adapter Ground motor Wall Hydrant Pressure Gauge before connecting Pressure to electrical power supply. Relief Valve Service Tee Hose Adapter Failure to ground motor can High Pressure Reinforced Hose Inlet cause severe or...
  • Página 8 Installation (Continued) 3 Phase 3 Phase LOW VOLTAGE HIGH VOLTAGE GROUND LOW VOLTAGE HIGH VOLTAGE (WHEN REQ) T7 T1 LINE LINE LINE LINE IL1231 IL1229 Figure 11 - Wiring Diagram for Baldor TEFC 3 Phase Figure 13 - Wiring Diagram for Marathon TEFC 3 Phase motors motors 3 Phase...
  • Página 9 Installation (Continued) Operation Unit must be full of fluid before Specific Wiring Procedure (Refer to Figures 9, 10, 11, 12, operating. Do not run dry, or against a 13, 14 and Minimum Wire Size Chart). closed discharge. Do not pump dirty a.
  • Página 10: Pump Disassembly

    Operation (Continued) With the strap wrench, loosen the barrel, turning CCW (counter clockwise). DO NOT use pipe wrench on pump START - UP PROCEDURE barrel. Once the preceding instructions have been completed, the Holding the impeller stack in place, position pump in pump can be started.
  • Página 11: Motor Replacement

    Maintenance (Continued) If damage to Stage components is evident, a complete cartridge assembly or individual stage assemblies are IMPORTANT: Do not scratch seal face. available for replacement (See Replacement Parts List). Dispose of cardboard washer and recheck seal face to Reassembly should follow the reverse order of the be sure it is free of dirt, foreign particles, scratches and disassembly procedure with special care given to...
  • Página 12: Troubleshooting Chart

    Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump won’t 1. Blown fuse or open circuit breaker 1. Replace fuse or close circuit breaker. See wire size chart for start or run proper break/fuse size at full speed 2. Power supply in OFF position 2.
  • Página 13 Booster Pump Parts Drawing ITEM NO. DESCRIPTION Motor †Governor †Switch Motor Seal, Rotary Barrel Discharge Head Discharge Bearing O-ring (2) Plate, Diffuser Impeller Diffuser Diffuser Bearing Shim as Required IL0127 Shaft and Coupling Assembly Mounting Ring Hex Head Bolts (4) †MotorAccess Cover Figure 19 †Screws, Access Cover (2)
  • Página 14 PRESSURE BOOSTER PUMP REPAIR PARTS FORM NO. FW0045 1114 (For Pricing Refer To Repair Parts Price List) SUPERSEDES 0813 Replacement Motors IL0565 POWDER STAINLESS POWDER STAINLESS ITEM REPLACEMENT MOTORS CAST IRON CAST IRON COATED STEEL COATED STEEL SINGLE PHASE 60 HZ THREE PHASE 60 HZ ODP NEMA J 1/3 HP 98J103...
  • Página 15 PRESSURE BOOSTER PUMP REPAIR PARTS FORM NO. FW0046 1114 (For Pricing Refer To Repair Parts Price List) SUPERSEDES 0312 IL0565 POWDER STAINLESS ITEM DESCRIPTION CAST IRON COATED STEEL 5 - 7 - 10 - 19 GPM, Discharge Head 3/4” NPT 132000 136905 136640...
  • Página 16: Bombas Elevadoras De Presión

    Instrucciones de funcionamiento y manual de piezas Por favor lea y guarde estas instrucciones. Lea cuidadosamente antes de tratar de armar, instalar, operar o darle mantenimiento al producto descrito. Protéjase usted y a los demás respetando toda la información de seguridad. ¡El incumplimiento de las instrucciones podría resultar en lesiones personales y/o daños materiales! Conserve las instrucciones para referencia futura.
  • Página 17: Datos Del Motor Monofásico 60 Hz

    De hierro fundido kW (HP) Etapa Salida – metros cúbicos por hora (galones por minuto) descarga inoxidable epóxico (PSI) DN (NPT) pulverizado (NPT) Modelos 60 Hz PB0508S031 PB0508C031 PB0508A031 0.25 (1/3) 10.2 PB0512S051 PB0512C051 PB0512A051 0.37 (1/2) 10.0 PB0516S071 PB0516C071 PB0516A071 0.55 (3/4)
  • Página 18: Datos Del Motor Trifásico

    Datos del motor trifásico Tabla D Trifásico † 60/50 Hz 3450/2850 RPM arranque por capacitor Factor de servicio Rotor bloqueado Voltaje Voltaje Amperes del Motor Amperes del motor del motor Código KW (HP) del motor conectado alfabético 230V 460V 230V 460V en fábrica 0.55 (3/4)
  • Página 19 Información general de seguridad 10. Asegure la línea de descarga antes de arrancar la bomba. Una línea de descarga que no esté asegurada puede Lea y cumpla cuidadosamente todas las instrucciones de moverse y posiblemente causar lesiones personales y/o seguridad en este manual y en la bomba. Mantenga las daños materiales o perforaciones.
  • Página 20: Instalación De La Bomba

    IMPORTANTE: es necesario hacer todo No hay fugas de Un compuesto para Los hundimientos aire en juntas de tuberías el sistema a prueba de aire y agua para hundimientos permiten bolsas de aire dañará el plástico la tubería de lograr un funcionamiento eficiente y entrada correcto.
  • Página 21 Bomba empleada para elevar la presión urbana de entrada (funcionamiento Instalación (continuación) automático). La instalación de un manómetro Suministro de la calle en el tubo de entrada cerca del puerto de entrada (vea la Figura Válvula de paso Caja de alimentación Unión Válvula de 6) indicará...
  • Página 22 Instalación (continuación) Bomba usada para elevar la presión de entrada de un hidrante de pared (funcionamiento manual). Adaptador de manguera Conecte el motor a tierra antes de conectarlo Hidrante de a una fuente de Manómetro pared alimentación eléctrica. Válvula de descarga de presión No conectar el Adaptador de...
  • Página 23 Instalación (continuación) TRIFÁSICO TRIFÁSICO VOLTAJE BAJO VOLTAJE ALTO LA TIERRA VOLTAJE BAJO VOLTAJE ALTO ELÉCTRICA (Cuando Requerido) T7 T1 LÍNEA LÍNEA LÍNEA LÍNEA IL1231 IL1229 Figura 11 - Diagrama de cableado para motores Figura 13 - Diagrama de cableado para motores trifásicos Baldor TEFC trifásicos Marathon TEFC TRIFÁSICO...
  • Página 24: Protección Del Motor

    Instalación (continuación) Todos los motores (monofásicos y trifásicos) deberían ser equipados con un interruptor de desconexión con fusibles Procedimiento específico para el cableado (consulte las correctos para proporcionar protección. Consulte el Código Figuras 9, 10, 11 12, 13, 14 y la Tabla del tamaño mínimo Eléctrico Nacional de los Estados Unidos u otros códigos de cables).13, 14 and Minimum Wire Size Chart).
  • Página 25: Mantenimiento

    Funcionamiento (continuación) Enrosque el tubo dentro del puerto de entrada de la bomba. Esto funciona como una manija. PROCEDIMIENTO DE ARRANQUE Usando la llave para tuberías, retire la carga de descarga Una vez que haya seguido las instrucciones anteriores, puede girándola en sentido contrario al de las manecillas del arrancar la bomba.
  • Página 26: Reemplazo Del Motor

    Mantenimiento (continuación) REENSAMBLAJE DE LA BOMBA Antes de reensamblar la bomba, inspeccione las IMPORTANTE: No raye la superficie del sello. piezas componentes del conjunto del cartucho (etapa) Deseche la arandela de cartón y vuelva a verificar que cuidadosamente para ver si hay daños, desgaste o la superficie del sello esté...
  • Página 27: Tabla De Solución De Problemas

    Tabla de solución de problemas Síntoma Posible(s) causa(s) Acción correctiva La bomba 1. Fusible fundido o disyuntor abierto 1. Reemplazar fusible o cerrar disyuntor. Consultar la tabla de tamaños de no arranca cable para obtener el tamaño correcto del disyuntor/fusible o no 2.
  • Página 28: Plano De Piezas De Bombas Elevadora De Presión

    Plano de piezas de bombas elevadora de presión Nº de DESCRIPCIÓN COMPONENTE Motor †Regulador †Interruptor del motor Sello, giratorio Cilindro Carga de descarga Rodamiento de descarga Junta tórica (2) Figura 19 Placa, difusor IL0127 Impulsor Difusor Rodamiento de difusor Arandelas para calzar según se requiera Conjunto de eje y acoplamiento Anillo de montaje...
  • Página 29: Piezas De Repuesto Para Bombas Elevadoras De Presión

    PIEZAS DE REPUESTO PARA BOMBAS FORM NO. FW0045S 1114 ELEVADORAS DE PRESIÓN SUPERSEDES 0813 (Para precios, consulte la Lista de precios de las piezas de repuesto) Motores de repuesto IL0565 RECUBRIMIENTO RECUBRIMIENTO HIERRO ACERO HIERRO ACERO COMP. MOTORES DE REPUESTO CANT.
  • Página 30 PIEZAS DE REPUESTO PARA BOMBAS ELEVADORAS DE PRESIÓN (Para precios, consulte la Lista de precios de las piezas de repuesto) FORM NO. FW0046S 1114 Supersedes 0312 IL0565 RECUBRIMIENTO ACERO COMP. DESCRIPCIÓN CANT. HIERRO FUNDIDO EPÓXICO INOXIDABLE PULVERIZADO 1,1 - 1,6 - 3,4 - 4,3 M³/H Carga de descarga DN20 (3/4 pulg.