5-
Project/bead display
At the top left, the project name and
bead number are displayed.
(The bead number is automatically
incremented and cannot be modified)
The «Explore» function allows you to access the list of work sessions created, sort them and also delete them.
The pictogram
shows the details of each session with the following information: sampling frequency, number of recorded beads, total
welding time, welding current supplied, configuration of each bead (process, time stamp, welding time and welding U-I).
The transfer of this information is done by exporting the data to a USB key.
The CSV data can be processed using spreadsheet software (Microsoft Excel
ENERGY MODE
This mode developed for welding with energy control framed by a DMOS allows, in addition to the energy display of the bead after welding, to set:
The thermal coefficient according to the standard used: 1 for ASME standards and 0.6 (TIG) or 0.8 (MMA/MIG-MAG) for European standards. The
displayed energy is calculated by taking this coefficient into account.
TROUBLESHOOTING, CAUSES, SOLUTIONS
SYMPTOMS
The wire feed is not constant.
The wire feed motor does not work.
Bad wire feeding.
No current or bad welding current.
The wire forms a bottleneck after the rollers.
38
RC-HD2
6-
Identification
At each end of the cord, an identifica-
tion window is displayed: Pass number,
Weld number, Temperature of the plate
and/or length of the cord.
, Calc OpenOffice
®
POSSIBLE CAUSES
Debris are blocking the hole.
The wire is spinning on the rollers.
One of the rollers is spinning.
The torch cable is entangled.
The brake on the reel or roller is too tight.
The wire liner is dirty or damaged.
The pin of the roller axis is missing
The brake of the reel is too tight.
Bad connection at the mains plug.
Bad earth connection.
No power.
The wire liner is crushed.
The wire is blocked in the torch.
No capillary tube.
Wire speed is too high.
7-
Validation
The validation can be done using the
interface or by pulling the trigger.
, etc.).
®
SOLUTIONS
Clean or replace the contact tip and apply an anti-
sticking solution.
Apply an anti-sticking solution.
Check the tightening of the roller screw.
The torch cable must be as straight as possible.
Loosen the brake and rollers
Clean or replace.
Reposition the pin
Release the brake.
See the plug connection and check if the plug is
properly powered.
Check the earth cable (connection and clamp).
Check the torch trigger
Check the liner and the torch.
Replace or clean.
Check the presence of the capillary tube.
Reduce the wire speed.