4.

SPECIFICATIONS

4.1.
General specifications
Measured parameters
L / C / R / D / Q / θ
Circuit mode
Parallel mode :
Series mode :
Displays
L / C / R :
D / Q / θ :
Measurement terminals : 4 BNC connectors + protective ground
Protection voltage :
Ranging mode :
Test frequency :
Freq. accuracy :
Test signal level :
Response time :
Temperature coefficient : 0.15 x (specified accuracy) / ° C
Operation temperature :
Storage temperature :
Consumption :
Protective fuse :
Power supply :
Dimensions :
Weight :
Accessories
1set of test alligator clips (2 BNC connections)
1 power cord
1 user's manual
optional
SMD Tweezers (4 BNC connections) ... HX0081
II - 40
Capacitance and resistance (default)
Inductance (default)
max. display 9999
max. display 999
5 V with respect to earth
auto and manual
100 Hz / 120 Hz / 1 kHz / 10 kHz
± 0.1 % (Measurement rate : 1 sec / 1 component)
0.8 Vrms approx.
approx. 1 sec / device under test (in manual range)
for all changes higher than 1% of full sale
(0° C -18° C or 28° C - 40° C)
0° C to 40° C ; 70 % R. H. max
-20° C to 50° C ; 80 % R. H. max
15 W max.
0,1 A / 250 V (input protective)
AC 100/120V, 50/60 Hz - Fuse : T 125 mA
AC 220/240V, 50/60 Hz - Fuse : T 63 mA
261 mm x 211 mm x 71 mm
1,6 kg
IX 3131B