No: 25711 – 10/18 rev. 3
Catalog Number • Numéro de Catalogue • Número de Catálogo: LMIN-104
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
LMIN-104-U is BAA and TAA compliant (Product produced in the U.S.)
This unit is pre-set for Plug n' Go™ operation,
adjustment is suggested.
For full operational details, adjustment and more features
of the product, see the DLM System Installation Guide
provided with Wattstopper room controllers, and also
available at www.legrand.us/wattstopper.
Installation shall be in accordance with all applicable
regulations, local and NEC codes. Wire connections shall
be rated suitable for the wire size (lead and building wiring)
employed.
For Class 2 DLM devices and device wiring: To be
connected to a Class 2 power source only. Do not reclassify
and install as Class 1, or Power and Lighting Wiring.
The LMIN-104 Digital Input Interface Module allows integration of 3rd party devices to the Wattstopper Digital Lighting Management
Local Network (DLM). The LMIN-104 connects to the DLM local network. In addition to On/Off control of loads, it can dim loads up and
down, or send messages such as After Hours, Shed, or Force On to the DLM local network based on external inputs.
The LMIN-104 operates on power from the DLM local network. It also provides input
terminal connections and options for converting input signals from 3rd party devices into
load controlling messages for the DLM system.
Four input terminals are provided for load control, group control, or generating DLM
scenario messages such as Force-ON, Force-OFF, load shedding, and cleaning functions.
Input terminals 1, 2, 3, and 4 are for connection of maintained or momentary switch closure
inputs, or third party logic inputs. Input signals may come from a wide variety of devices
including building automation systems, time clocks, and key switches.
By default, the LMIN-104 inputs accepts 2-wire momentary contacts to control DLM loads. If
2-wire maintained contracts, or 3-wire momentary contacts are needed, they can be set up
using LMCS software.
The LMIN-104 can also be changed via LMCS software so that it can be used as a partition
interface, for connection to an analog Wattstopper occupancy sensor, or for connection
to an remote photocell (functions previously performed by the LMIO-102, LMIO-201 and
LMIO-301 respectively).
NOTE: If an isolated low voltage relay is required, the LMOR-102 provides this functionality.
Using the LMIN-104 with LMCS
The LMIN-104 has three operating modes: Normal, Partition, and Photocell. By default it is set to Normal mode. LMCS-100 software
is required to select another mode. The mode is set for the entire LMIN-104—you can't have some inputs set to one mode and others
set to another.
While in Normal mode, you can choose between a Switch Input or Sensor Input. When using a switch input, seven Switch modes are
available, which determine the type of message sent to the DLM network. Again, switching selecting a value other than the default
requires LMCS. The available functions are: Load Control (the default, which switches Loads ON/OFF), Normal/After Hours, Load
Shed, Clean Switch, Force On, Force Off, and Key Switch.
If using a sensor input, the LMIN-104 can be used to control Loads or Scenes.
NOTE: In Normal mode, each input is independent and can be set to a different value. For example, you could use inputs 1 and 2 for
momentary switches, input 3 for a maintained switch, and input 4 for an occupancy sensor. However, since a 3 Wire Rocker
Dimmer switch uses two input wires, it requires use of either inputs 1 and 2, or 3 and 4. Therefore, when selecting that value for
input 1 or 3, the corresponding input 2 or 4 will be disabled in LMCS.
Wattstopper
DLM - Digital Input Interface Module
DLM – Module d'interface à entrée numérique
DLM: Módulo de interfaz de entrada digital
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
DESCRIPTION
OPERATION
®
SPECIFICATIONS
Voltage .................................................................24VDC
Current Consumption ............................................. 20mA
Power Supply ....................Wattstopper Room Controller
Connection to the DLM Local Network .......2 RJ-45 ports
Environment ....................................For Indoor Use Only
Operating Temperature ... 32° to 104°F (0° to 40°C)
Storage Temperature ..... 23° to 176°F (-5° to 80°C)
Relative Humidity ......... 5 to 95% (non condensing)
RoHS compliant, UL2043 Plenum rated
Patent Pending
Connect to
1
DLM local network
NOT Ethernet
2
3
4
Input 1
Input 2
Input 3
Input 4
+24VDC
Blue LEDs
LED 1
LED 2
LED 3
LED 4
24V Overload
Photocell In
GND
+24VDC
+24VDC
+24VDC

Publicidad

Tabla de contenido
loading

Resumen de contenidos para LEGRAND Wattstopper LMIN-104

  • Página 1 Power Supply ....Wattstopper Room Controller provided with Wattstopper room controllers, and also Connection to the DLM Local Network ..2 RJ-45 ports available at www.legrand.us/wattstopper. Environment ........For Indoor Use Only Operating Temperature ... 32° to 104°F (0° to 40°C) Installation shall be in accordance with all applicable Storage Temperature ..
  • Página 2 LMCS window for an LMIN-104 set to Normal mode. MOUNTING AND WIRING CAUTION: TO CONNECT A COMPUTER TO THE DLM LOCAL NETWORK USE THE LMCI-100. NEVER CONNECT THE DLM LOCAL NETWORK TO AN ETHERNET PORT – IT MAY DAMAGE COMPUTERS AND OTHER CONNECTED EQUIPMENT. Installation shall be in accordance with all applicable regulations, wiring practices, and codes.
  • Página 3: Terminal Connections

    TERMINAL CONNECTIONS Maintained Switch 2 Wire Momentary Switch 3 Wire Momentary Switch (1) Input 1 (1) Input 1 (1) Input 1 for Switch 1 (2) Input 2 (2) Input 2 (3) Input 3 for Switch 2 (3) Input 3 (3) Input 3 (4) Input 4 (4) Input 4 (2) Input 2 for Switch 1...
  • Página 4: Normal Mode

    NORMAL MODE Switch Inputs When set to the default Normal Mode, the LMIN-104 defaults to an Input Type of “Switch”, with the Switch Mode set to “Load Control”. When set this way, a non-DLM low voltage switch can turn any loads bound to that switch ON and OFF. However, there are several other specialized commands that can be triggered from a switch input.
  • Página 5 PARTITION MODE You must select “Partition” in the Operating Mode drop-down in LMCS in order to put the LMIN-104 into Partition Mode. The LMIN-104 device allows a DLM system to automatically reconfigure the DLM devices in a space that has up to four movable walls. Each combination of walls being Open or Closed is called a Profile in the DLM system;...
  • Página 6 PARTITION EXAMPLES on Examples Profile 1 0 Walls (Default Room) Profile 1 Profile 2 1 Wall (2 op ons) Profile 1 Profile 2 Profile 3 Profile 4 2 Walls (4 op ons) Profile 1 Profile 2 Profile 3 3 Walls (8 op ons) Profile 4 Profile 5...
  • Página 7 PHOTOCELL MODE Photocell Mode is an ideal solution for any application where exterior lighting needs to be controlled based on actual ambient exterior light levels such as parking, site and landscape lighting. Applications with large expanses of skylight, clearstory or atrium glazing can also benefit from controlling lighting based on ambient light entering the building through the glazing.
  • Página 8 DLM fourni avec Wattstopper contrôleurs de pièce et aussi disponible au Branchement au réseau local DLM ....... 2 ports RJ-45 www.legrand.us/wattstopper. Environnement ......Pour usage intérieur seulement Température de fonctionnement ... 0 à 40 °C (32 à 104 °F) L’installation doit être effectuée conformément à...
  • Página 9: Montage Et Câblage

    La fenêtre du LMCS pour un LMIN-104 réglé en mode normal. MONTAGE ET CÂBLAGE ATTENTION : POUR CONNECTER UN ORDINATEUR AU RÉSEAU DLM LOCAL, UTILISER LE LMCI-100. NE BRANCHEZ JAMAIS LE RÉSEAU DLM LOCAL À UN PORT ETHERNET – CELA POURRAIT ENDOMMAGER LES ORDINATEURS AINSI QUE LES AUTRES ÉQUIPEMENTS CONNECTÉS.
  • Página 10 RACCORDEMENT DES CONNECTEURS Contact maintenu Contact momentané à 2 fils Contact momentané à 3 fils (1) Entrée 1 pour interrupteur 1 (1) Entrée 1 (1) Entrée 1 (3) Entrée 3 pour interrupteur 2 (2) Entrée 2 (2) Entrée 2 (3) Entrée 3 (3) Entrée 3 (2) Entrée 2 pour interrupteur 1 (4) Entrée 4...
  • Página 11: Mode Normal

    MODE NORMAL Interrupteur d’entrées Lorsque le système est en mode normal par défaut, le LMIN-104 prend implicitement pour valeur une entrée de type « interrupteur » et le mode d’interrupteur est réglé à « Contrôle de charge ». Ainsi réglé, un interrupteur basse tension n’étant pas sur le réseau DLM peut transformer toutes charges reliées à...
  • Página 12: Profils De Charge

    Câblage pour l’entrée d’un détecteur BZ-150 Rouge Blanc Neutre Noir Rouge 120VCA Circuit 277VCA Câbles de basse tension Blue LEDs Connect to LED 1 DLM local network NOT Ethernet LED 2 Orange Gris LED 3 LED 4 Brun Bleu 24V Overload Contrôle Tout détecteur Commun...
  • Página 13: Exemples De Partition

    EXEMPLES DE PARTITION Exemples de par Profil 1 0 mur (Pièce par défaut) Profil 1 Profil 2 1 mur (2 op ons) Profil 1 Profil 2 Profil 3 Profil 4 2 murs (4 op ons) Profil 1 Profil 2 Profil 3 3 murs (8 op ons) Profil 4...
  • Página 14 MODE DE CELLULE PHOTOÉLECTRIQUE Le mode de cellule photoélectrique est une solution idéale pour toute application nécessitant un éclairage extérieur à contrôler selon les intensités d’éclairage d’un environnement extérieur comme un parc de stationnement, une installation ou un jardin éclairé. Les applications avec une grande quantité...
  • Página 15: Especificaciones

    Fuente de alimentación ..Controlador de habitación de Wattstopper proporciona con los controladores de habitación Wattstopper; también Conexión a la red local DLM ........2 puertos RJ-45 está disponible en www.legrand.us/wattstopper. Entorno ............Solo para uso en interiores Temperatura de funcionamiento....0 a 40 °C (32 a 104 °F) La instalación debe realizarse conforme con todas las...
  • Página 16: Montaje Y Cableado

    Ventana LMCS para un LMIN-104 configurada en el modo Normal. MONTAJE Y CABLEADO PRECAUCIÓN: PARA CONECTAR UNA COMPUTADORA A LA RED LOCAL DE DLM, USE EL DISPOSITIVO LMCI-100. NUNCA CONECTE LA RED LOCAL DE DLM A UN PUERTO ETHERNET: PODRÍA DAÑAR LAS COMPUTADORAS Y OTROS EQUIPOS CONECTADOS. La instalación debe realizarse conforme con todas las reglamentaciones aplicables, las prácticas de cableado y los códigos.
  • Página 17: Conexiones De Terminales

    CONEXIONES DE TERMINALES Interruptor mantenido Interruptor momentáneo de 2 cables Interruptor momentáneo de 3 cables (1) Entrada 1 para Interruptor 1 (1) Entrada 1 (1) Entrada 1 (3) Entrada 3 para Interruptor 2 (2) Entrada 2 (2) Entrada 2 (3) Entrada 3 (3) Entrada 3 (2) Entrada 2 para Interruptor 1 (4) Entrada 4...
  • Página 18: Modo Normal

    MODO NORMAL Alternar entradas Cuando está configurado en el modo Normal predeterminado, el LMIN-104 usa de forma predeterminada un tipo de entrada de "Interruptor" con el modo de Interruptor configurado en "Control de carga". Cuando está configurado de este modo, un interruptor de bajo voltaje no DLM puede ACTIVAR o DESACTIVAR cualquier carga unida a ese interruptor.
  • Página 19: Modo De Partición

    Cableado para una entrada de sensor BZ-150 Rojo Blanco Neutro Negro Rojo 120VCA Vivo 277VCA Cables de bajo voltaje Blue LEDs Connect to LED 1 DLM local network NOT Ethernet LED 2 Naranja Gris LED 3 LED 4 Marrón Azul 24V Overload Control Cualquiera...
  • Página 20: Ejemplos De Particiones

    EJEMPLOS DE PARTICIONES Ejemplos de par ciones Perfil 1 0 paredes (Habitación predeterminada) Perfil 1 Perfil 2 1 pared (2 opciones) Perfil 1 Perfil 2 Perfil 3 Perfil 4 2 paredes (4 opciones) Perfil 1 Perfil 2 Perfil 3 3 paredes (8 opciones) Perfil 4 Perfil 5...
  • Página 21: Solución De Problemas

    MODO FOTOCELDA El modo Fotocelda es una solución ideal para cualquier aplicación en la que se necesita controlar la iluminación exterior según los niveles de luz exterior ambiental reales, como la iluminación de estacionamientos, sitios y paisajes. Las aplicaciones con amplias extensiones de tragaluces, claristorios o atrios también se pueden beneficiar de controlar la iluminación según la luz ambiente que entra al edificio a través de los vidrios.
  • Página 22 No. 25711 – 10/18 rev. 3 © Copyright 2017 Legrand All Rights Reserved. 800.879.8585 © Copyright 2017 Tous droits réservés Legrand. www.legrand.us/wattstopper © Copyright 2017 Legrand Todos los derechos reservados.

Tabla de contenido