897 Service Sink
INSTALLATION INSTRUCTIONS
REFER TO PAGE 6 FOR ILLUSTRATION.
1. Water supplies must be shut off. Supply lines must have 1/2" NPT male threaded ends and
should protrude 5/8" – 7/8" from the finished wall on 8" centers. Supply lines must be secured to
support the faucet.
2. Apply pipe sealant to the 1/2" NPT threads of the supply lines.
3. Remove supply arms from faucet and screw onto supply lines. (See Fig. 1) Position the supply
arms so they line up with the faucet inlets (8" center to center).
NOTE: The faucet must be mounted level, adjust supply arms as necessary.
4. Place the flanges over the supply arms and against the finished wall. (See Fig. 1)
5. Make sure inlet gasket is sitting in place within the union nut. (See Fig. 1) Attach faucet to supply
arms and tighten union nut securely.
6. Remove the set screw from the brace rod. Place the brace rod in the slot on the spout and
reattach the set screw using 3/32" hex key wrench. (See Fig. 2)
7. Place brace flange against the finished wall and center it with the spout. Secure the flange to the
wall using (2) wood screws provided.
NOTE: Finished wall must be supported where the brace flange mounts to the wall to provide
maximum support.
8. Turn on water supply and check supply lines and faucet connections for leaks.
SERVICE INSTRUCTIONS
1. The faucet is furnished with integral supply stops. To shut off water supply, screw stops in using
5/16" hex key wrench until water is shut off. Open the supply stop no more than three (3)
complete turns.
NOTE: Stop can unscrew completely causing water to spray out from the stop opening.
2. For adjustment of cartridges, refer to page 7.
3