Step 3: Position the gasket included on the coverplate and connect the
black wires from both fixtures to the black house supply wire and
the white wires from both fixtures to the white supply wire using
the wire nuts provided.
Attach the ground wire
coming from your
house to the copper
ground wires from both
fixtures using wire nuts
provided. If no house
ground wire is available,
attach both copper
ground wires from the
fixture to the junction
box if it is metal and
grounded. If junction
box is not metal and no
house ground wire is available, an alternative ground source
must be used for safe operation. (See Fig. 5 for wiring diagram.)
Step 4: Position the coverplate over the junction box and insert the 1-1/2˝
screw included through the center hole in the coverplate and tighten
into the junction box mounting bracket installed in Step #2. Be sure
no loose wires remain sticking out from underneath the coverplate.
Step 5: Apply silicone caulk around the edges of the coverplate to provide a
watertight seal from rain and moisture.
Step 6: Turn on power at main fuse/breaker box.
Note: This fixture can be used with a dimmer switch to adjust light output. To
install a dimmer switch: Use a dimmer switch designed for incandescent light-
ing that has a rating of 300 watts or higher. Follow the installation instructions
included with the dimmer switch. Keeping the halogen bulb in a dim mode for
an extended period of time may shorten the life of the bulb. To achieve maxi-
mum bulb life, occasionally turn the switch to full brightness for a few hours.
For optimum performance quartz halogen fixtures must be mounted so that the
bulb is within 4° (degrees) of horizontal. Adjust fixture vertically to desired posi-
tion and tighten swivel bolt securely.
Servicing your fixture
CAUTION: When replacing bulb in the fixture, always replace with the
same wattage bulb or a lower wattage bulb. DO NOT replace with a
bulb of greater wattage than specified on the fixture. To do so could
create a fire hazard and or shorten the life of the bulb.
How to replace bulb
Note: Make sure that power to the fixture is off and that the fixture is cool.
Step 1: Remove glass lens cover by first removing the two (2) screws in the
back of the housing that hold glass lens cover in place.
Step 2: Push bulb into the spring-loaded socket and pull other bulb end out of
opposite socket.
Call for customer service and/or missing or damaged parts (800-334-6871)