Cleaning or Replacing Inlet Filter
1
Close supply valves
2
Disconnect braided hoses and clean or replace filter
(for a new filter, see "common replacement parts")
Connect braided hoses with filter to supply valves and
fully open.
3
Cold water > white label
Warm water > no label
Result
The filter is now cleaned or replaced.
Chicago Faucets E-Tronic
Adjusting Water Temperature (Internal Mixer)
These instructions apply to all DC models.
1
Remove shut-off screw
2
Remove housing vertically
Adjust internal mixer with screwdriver
3
Clockwise > warm
Counterclockwise > cold
4
Mount housing vertically
9
™