Diagnostics Led - WimTec SanTec FLUSH Instrucciones Para El Montaje Y El Funcionamiento

Tabla de contenido

Publicidad

GB
Adjustment of flushing programs
Adjustment of flushing programs (only possible in the first 10 s after initia-
tion): as soon as battery or mains adaptor will be connected
(program 2 factory-made pre-adjusted)
1.
12V version: connection to power supply
6V version: insert batteries
For changing the flushing program of an already adjusted WC-control, the power
supply must be disconnected (disconnect external power supply unit or remove the
batteries) for at least 30 s, afterwards a new programming is possible.
2.
The device makes a selftest, then the diagnostics LED flashes 3 times quick. From
that time there are 10 s for adjusting the flushing program.
3.
Via close range reflex (hold hand approx. 2 cm in front of infrared window=> see
picture) it is possible to choose between 3 different programs.
*
1 slow flash = program 1
no automatic flushing - via close range reflex only manual flushing releasable
**
2 slow flashes = program 2 (preset)
as program 1, but additional automatic flushing after leaving the WC
minimum stay time 15 s
*** 3 slow flashes = program 3
as program 2, but additional intermediate flushes every 10 min. for
handicapped areas minimum stay time 15 s
4.
Remove hand at the desired program - the control confirms the program by flashing
twice quickly.
5.
Afterwards there are further 10 s for changing the flushing program again. After
lapse of this time, the device flashes 3 times quickly and it changes into normal
function.

Diagnostics LED

Red LED flashes at
wide range reflex
during the first 5
minutes after initi-
ation.
19

Publicidad

Tabla de contenido
loading

Tabla de contenido