Tubing Connections and Soap Pump Installation
1. Remove Existing B-822 Dispenser pump(s), Soap Bottle(s) and Cap(s), if applicable.
Caution - Black rubber must be between plastic shank and countertop.
2. If existing B-822 Shank is 6" long, you may cut shank at non-threaded area in the
center with a PVC cutter or hack saw, if desired.
Thick Countertop
Installer Note:
If counter top is more than 1-3/4'' (45mm) thick, use standard 6''
(105mm) shank (Part No. 822-408) without cutting it. 8" (205mm)
clearance under top surface of counter is required.
For new installations, mount 8221-408 Short Shank 3" (75mm) for installation in most
countertops or 822-408 Long Shank 6" (150mm) for countertops thicker than 1-3/4"
(45mm). Make sure countertop surface around mounting hole is clean and free of
soap residue. Insert Shank through 1" (25mm) diameter hole. Make sure the Black
Rubber Washer is in place between the countertop and Shank. Place 822-43 Rosette
Washer and Retaining Nut onto Shank under counter top. Tighten Retaining Nut
against underside of countertop.
Caution: Do not over-tighten Retaining Nut.
3. Connect 830-313 vertical tubes to 3-barb connections of all Soap Pump Cylinders.
Make sure tube is completely engaged on the Cylinder fittings.
Form No. 830-569 r11/13/12