At the end of the conversation the system will return to the main screens 1 and 2.
The Installer
The installer will have access to a Configuration Menu, through a code that must introduce after
pressing the keys C y
By default, the code to enter the Configuration Menu is '1' .This code can be changed in the
Configuration Menu by another one longer, of up to 9 digits, so that it is practically impossible
that a user introduces it accidentally. It is very recommendable to make this change and do not
forget the new code.
Configuration Menu (C +
In this menu the parameters of the panel can be set up. In order to navigate between the parameters
key C must be pressed, and to change and confirm between the different options from each
parameter key
be done with the numeric keypad and confirmed with
LANGUAGE. Select language
o
OPENING CODES. 4 different common opening codes up to 6 digits exist. By default, these
o
codes will be: 101010, 202020, 303030, and the 404040. Programming an opening code with
the value `000000' is equivalent to disable this code.
OPENING TIME. There are 2 different configurable "Opening Times". The first one will be
o
used when the user is outside the building (that is when we call to a flat and someone opens
the door, also when we introduce an 'Opening Code') and the second one if the user is inside
the building (pressing the hall-button inside the building; this opening time is usually longer).
By default the Time1=2 seconds and the Time2 = 5 s. (Max Time for both = 9 seconds).
PANEL. A statement whether the panel is installed as internal (direct call to monitors) or
o
external (call via SDL).
SELFSTART. The selfstarting function from the monitor is enabled by default. In this menu
o
you can disable and enable it.
PUSHBUTTONS CODIFICATION. Each pushbutton has assigned a position from 1 to 66
o
due to the internal wiring of the panel and by default this code is generated when the
corresponding pushbutton is pressed. In this menu, it is allowed to change the call code that is
generated when each of the 66 pushbuttons is pressed. Values from 1 to 255 are admitted for
internal panel. For pushbutton external panel must fill in the SDL field (between 1 and 63)
and the monitor field (between 1 and 99). This menu is very useful if in the installation
coexist pushbutton panels and keypad/display panels. This option will be applied in
pushbuttons panels by connecting a keypad/display to assign call codes and disconnecting it
when the operation finishes.
NEW ACCESS CODE. It is strongly recommended to change the code of the Configuration
o
Menu. By default this code is '1', and to change it, the new code must be typed in the keypad
and confirmed with
In order to leave this menu, we must navigate through the different parameters pressing the C key,
looking for the message 'EXIT?'. When this message is shown in the screen, press
will return to the main screens 1 and 2.
(first one and then the other, not both at the same time).
+ Config. Menu Code ('1') +
must be pressed. If it is desired to change the values of some parameters it must
.
PLACA VISUALTECH – VISUALTECH PANEL
Funcionamiento -Functioning
. The parameters are the following ones:
14
)