4.2 Technical data PRA 84
Rated voltage
Maximum voltage during operation or during charging while
in operation
Charging time at 32 °C
Operating temperature
Storage temperature (dry)
Charging temperature
Weight
4.3 Technical data PRA 85
Mains power supply
AC frequency
Rated power
Rated voltage
Operating temperature
Storage temperature (dry)
Weight
4.4 Technical data PRA 92
Infrared communication type
Power source
Operating temperature
Storage temperature

5 Before use

5.1 Charging the battery
Note
This tripod must only be operated with the Hilti battery PRA 84.
▶ Charge the batteries fully before using them for the first time.
5.1.1 Charging the battery in the tool
WARNING
Electrical hazards. If liquids penetrate the tool, they may cause the AC adapter to short circuit and
explode. This may result in serious injury and cause burns!
▶ The PRA 85 AC adapter is for indoor use only.
1. Place the battery into the battery compartment.
2. Rotate the socket cover so that the charging socket on the battery can be seen.
3. Plug the cord from the AC adapter or motor vehicle power adapter into the battery.
4. Connect the AC adapter or the motor vehicle power adapter to the power supply.
Note
The current charge status is shown by the battery display on the tripod when it is switched on.
Printed: 21.07.2017 | Doc-Nr: PUB / 5070305 / 000 / 03
2
2
7.2 V
13 V
130 min
−20 ℃ ...50 ℃
−25 ℃ ...60 ℃
0 ℃ ...40 ℃
0.3 kg
115 V ...230 V
47 Hz ...63 Hz
36 W
12 V
0 ℃ ...40 ℃
−25 ℃ ...60 ℃
0.23 kg
2.4 GHz
2 AA batteries
−20 ℃ ...50 ℃
−25 ℃ ...60 ℃