6. Before use

6.1 Inserting new batteries
-NOTE-
Do not use damaged batteries.
Do not mix old and new batteries. Do not mix batteries
of different makes or types.
7. Operation & applications
-NOTE-
The pendulum is locked when the tool is in the closed
position (laser beam blinks).
7.1 Operation
7.1.1 Bringing the tool into the operating position
1. Open the tool to the 90° or 180° position.
2. Bring the reference line into alignment with (paral-
lel to) the top edge of the base section.
-NOTE-
The pendulum is able to swing freely when the refer-
ence line is parallel to the base section, when the pen-
dulum lockbutton is not pressed in and when the tool
is set up in a horizontal position (≤ ± 5°).
The laser beams blink rapidly when the tool is unable
to level itself automatically.
7.1.2 Switching on the laser beams
Switching on only the plumb beams (vertically upwards
and downwards):
1. Press the selector button once.
Switching on only the front and perpendicular beams:
1. Press the selector button twice.
Switching on the plumb beams, front beam and per-
pendicular beam:
1. Press the selector button three times.
Printed: 07.07.2013 | Doc-Nr: PUB / 5070096 / 000 / 00
1. Bring the two parts of the tool into the closed posi-
tion.
2. Press the battery compartment release button.
3. Pull the battery holder downwards out of the tool.
4. Replace the batteries.
-CAUTION-
Take care to observe correct polarity.
5. Close the battery compartment. Check that it engages
securely.
7.1.3 Switching the tool/laser beams off
1. Press the selector button repeatedly (1-3 times depend-
ing on previous operating mode) until the laser beam
is no longer visible and the LED no longer lights.
-NOTE-
The tool switches itself off automatically after approx.
15 minutes.
7.1.4 Deactivating the automatic cut-out
1. Press and hold the selector button (approx. 4 sec-
onds) until the laser beam blinks three times in con-
firmation.
-NOTE-
The tool will be switched off when the selector button
is pressed (between one and three times, depending
on operating mode) or when the batteries are exhausted.
7.2 Examples of applications
7.2.1 Vertical alignment (plumbing) of sections
of a steel structure
7.2.2 Vertical alignment of door and window
frames
7.2.3 Setting out drywall track for a partition
wall
7.2.4 Aligning pipe fastenings
en