Before Use; Operation - Hilti PMC 36 Manual De Instrucciones

Ocultar thumbs Ver también para PMC 36:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58

6. Before use

6.1 Inserting the batteries 2
DANGER
Use only new batteries.
1.
Bring the foot into the closed position.

7. Operation

NOTE
To achieve maximum accuracy, project the line onto
a vertical, even surface. When doing so, set up the
tool at 90° to the surface.
NOTE
When the foot section of the tool is in the closed
position, the pendulum is automatically locked (laser
beam blinks).
7.1 Operation
7.1.1 Bring the foot of the tool into the open
position.
1.
Pivot the foot to the 90° or 180° position.
2.
Bring the reference line parallel to the top edge
of the foot.
NOTE The pendulum is free to move only when
the reference line is parallel to the foot, when the
pendulum lockbutton is not pressed and when an
angle of 3.5° in each direction is not exceeded.
NOTE If the laser beam blinks rapidly, this indic-
ates that the tool is unable to level itself.
7.1.2 Switching on the laser beams
7.1.2.1 Switching on the vertical beams (two
points and a line)
Press the selector button once.
Printed: 07.07.2013 | Doc-Nr: PUB / 5071411 / 000 / 00
2.
Press the catch on the battery compartment.
3.
Pull the battery holder downwards away from
the tool.
4.
Remove the batteries from the packaging and
insert them in the tool.
NOTE Only batteries recommended by Hilti may
be used to power the tools.
5.
Check that the battery terminals are positioned
correctly as shown on the underside of the unit.
6.
Close the battery compartment. Check that the
catch engages properly.
7.1.2.2 Switching on the horizontal beams (two
points and a line)
Press the selector button twice.
7.1.2.3 Switching on all beams
Press the selector button three times.
7.1.3 Switching off the tool / laser beams
Press the selector button until the laser beam is no
longer visible and the LED goes out.
NOTE
The tool switches itself off automatically after approx.
15 min.
7.1.4 Deactivating the automatic power-off
Press and hold the selector button for approx. 4 sec.
until the laser beam blinks three times as confirma-
tion.
NOTE
The tool will be switched off when the selector button
is pressed (between one and three times, depend-
ing on operating status) or when the batteries are
exhausted.
7.1.5 Using the tool with the PMA 30 laser
receiver
For further information, please refer to the PMA 30
operating instructions.
en
19

Publicidad

Tabla de contenido
loading

Tabla de contenido