2. GENERAL RECOMMENDATIONS
Check voltage and frequency. The electrical terminal must be connected to
a magnetothermal cutout (compatible with the unit's power rating) and a
differential cutout with a minimum sensibility of 30 mA.
ELECTRICITY CONNECTION
ELECTRICITY CONNECTION
220/230 V.
50 Hz.
220/230 V.
Make sure that the tube that runs from the button to the junction box has
not been disconnected while the bathtub was being handled.
Once assembly is complete and the checks described in the preceding points
have been made, proceed to fill up the bathtub, making sure that water is 2
to 3 cm. higher than the level of the topmost jets. Check that all of the joints
of the hydromassage elements are watertight with the hydromassage system
running.
No bathtub should be started up until the entire unit is protected with its
corresponding bearings and/or skirtings (optionally supplied by Baños 10,
S.L.).
Seal the edges of the bathtub in contact with the wall with fungicidal silicone
or strips designed for this purpose. In the event that the optional skirting has
been chosen, it should not be sealed on any of its sides, so that it remains
removable.
We recommend that bathtubs always be installed with skirtings. In the event
that the bathtub is embedded with masonry work, a 30x40 cm. ventilated
access-cover should be included next to the motor, in order to facilitate the
cooling of and maintenance on the hydromassage system; failure to ventilate
the system may result in damage to it.
Our products should not be built in; in the event that they are, the costs
derived from extracting them for maintenance or repairs shall not be covered
by the Baños 10 guarantee.
We recommend that walls and the floor be tiled before installing the bathtub.
For bathtub-wall unions, we suggest that you use special profile sections that
Baños 10 can supply you with.
ELECTRICITY CONNECTION
60 Hz.
110/115 V.
60 Hz.
8. INSTALACIÓN
.
6.- Conectar el terminal eléctrico de la bañera
a la instalación fija de la casa, cuyo circuito
deberá estar protegido por interruptor mag-
netotérmico y un interruptor diferencial de
máximo 30 mA.
7.- Comprobar que durante la manipulación de
la bañera no se ha desconectado ningún
elemento.
8.- Una vez efectuada la instalación y realizadas
las pertinentes comprobaciones, proceder a
verificar la estanqueidad del conjunto de hidro-
masaje. Para ello proceder al llenado de la bañera
hasta el rebosadero, conectar el circuito de
alimentación y poner en funcionamiento el
equipo tal y como se indica en el manual de
usuario.
9.- Una vez comprobado que no hay ninguna
anomalía en la estanqueidad del conjunto
proceder a la fijación de los pies regulables al
suelo mediante tornillo y taco. En caso de
detectarse alguna anomalía en el funciona-
miento del equipo comunicar inmediatamente
con el distribuidor y abstenerse de continuar la
instalación.
10.- Una vez fijada la bañera proceder al cerra-
miento de los laterales a excepción de los que
llevan faldón (ver manual instalación faldón).
Proceder a sellar las uniones bañera-muro con
silicona fungicida o perfiles específicos.
¡ATENCIÓN! Los faldones deben ser remo-vibles.
No siliconarlos.