Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
GB
Applications
The factory settings of all GROHE infrared and radar fittings
can be changed using the infrared remote control.
The current settings are permanently stored in the fitting and
will not be lost in case of power failure.

Battery change

If the indicator (A) no longer flashes when a button is pressed,
the batteries should be checked, see fold-out page II.
Changing battery, see fold-out page II.
Check contacts, clean and if necessary replace batteries.
Only use Micro 1.5 V (AAA, LR03) type batteries.
Insert batteries with correct polarity.
Disposal note
Dispose of batteries in accordance with national
regulations.
Operation
1. In the case of basin fittings, start the water flow by
approaching the sensor system of the fitting.
In the case of urinal and WC fittings, allow an object to be
detected for at least 5 s by the infrared sensor system.
2. Point the remote control at the fitting from a distance of
between 20 and 50cm, and press a button within 10 s.
In the case of radar urinal fittings, adjustment and feedback
are performed via the electronic module.
• Each correct press of a button is confirmed by the indicator
lamp (A) flashing on the remote control, see fold-out page I.
If the indicator lamp does not flash, either button was not
pressed properly, or the batteries in the remote control are
empty, see Battery change.
• Each accepted remote control command is confirmed by
flashing of the indicator lamp in the sensor system of the
fitting. Please refer to the relevant functional descriptions
for the flashing intervals.
3. After each accepted remote control command, the fitting
remains receive-ready for a further 60 s.
Functions for all fittings
Restore factory settings (reset)
Function
Button
RESET
Restore factory
settings
> 3 s
The urinal and WC fittings enter into power-up mode
for 3 minutes following a RESET.
- Detected objects are indicated through the indicator lamp in
the sensor system of the fitting.
- There is no minimum delay, flushing is always perform at the
end of the detection period, regardless of the duration of
presence in the detection zone.
5
Indicator lamp
Set detection zone
Function
Button
Zoom area
Reduce area
Test mode – waterless simulation
In order to check and set the detection zone without flowing
water. The water flow is simulated by lighting up of the
indicator lamp in the sensor system.
Function
Button
TEST
Activate
Zoom area
Reduce area
TEST
Deactivate
or after 60 s
Battery voltage indicator
Check the remaining battery capacity.
Function
Button
TEST
Activate
TEST
The remaining capacity is then indicated as follows:
Remaining capacity > 60%
Remaining capacity > 40%
Remaining capacity > 20%
Remaining capacity < 20%
This function is available for battery-operated products with
a manufacturing date later than 01.02.2009.
Set run-on/flush duration
Function
Button
Increase
duration
Decrease
duration
Switch fitting off/on
Function
Button
OFF
Switch off fitting
AUTO
OFF
Switch fitting
back on
AUTO
Indicator lamp
Per stage:
End position:
Per stage:
End position:
Indicator lamp
Per stage:
End position:
Per stage:
End position:
Indicator lamp
(20x)
Indicator lamp
Per stage:
End position:
Per stage:
End position:
Indicator lamp
.....

Publicidad

Tabla de contenido
loading

Tabla de contenido