PERFORMANCE
Model
HP
5 ft.
63013
1/2
7.5
63023
3/4
9.0
63033
1
13.5
SAFETY INSTRUCTIONS
1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of
flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting
in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
5.
Wear safety goggles at all times when working with pumps.
6.
This is a dual voltage 115/230 V pump. VOLTAGE SELECTOR INSIDE PRESET TO 230V.For 115V selection, please
open the terminal cover and set the switch to the proper voltage. All wiring should be performed by a qualified
electrician.
7.
Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
8.
Ensure the electrical power source is adequate for the requirements of the pump.
9.
Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE
A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
10. The pump should be connected to a 230V/115V GFCI outlet protected with a 10 amp (230V)/20 amp (115V) fuse or
circuit breaker.
11. Know the pump and its applications, limitations, and potential hazards.
12. Secure the pump to a solid base.
13. Periodically inspect the pump and system components. Disconnect the pump from the power supply before inspecting.
14. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational
Safety and Health Administration (OSHA) guidelines must be followed.
15. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself
once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is
plugged in.
16. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time
when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may
cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems
and remedies.
GPM of Water @ Total Discharge Pressure of 40 psi
10 ft.
20 ft.
30 ft.
40 ft.
6.6
5.5
5.0
8.1
6.2
6.0
11.6
9.0
7.4
50 ft.
60 ft.
70 ft.
4.7
3.8
3.5
2.2
5.3
4.5
3.5
3.0
7.0
6.0
5.1
4.6
2
80ft
90ft
100ft
110ft
-
-
-
-
2
1.5
-
-
3.2
2
1.5
1
Max.
Pressure
shutoff
66PSI
67PSI
67PSI