Turn off the device and turn off the power before cleaning. Otherwise, it may cause an electric
shock.
•
Do not clean the air conditioner with excessive amounts of water.
•
Do not clean the air conditioner with flammable cleaning products. Flammable cleaning agents
can cause fires or deformations.
•
Turn off the air conditioner and turn off the power if you are not going to use it for a long time.
•
Turn off and unplug the unit during storms.
•
Make sure that the water condensation of the unit can drain without obstacles.
Do not operate the air conditioner with wet hands. It can cause an electric shock.
•
•
Do not use the device for any purpose other than the intended use.
•
Do not climb or place objects on the outdoor unit.
Do not allow the air conditioner to operate for long periods of time with the doors or windows open,
•
or if the humidity is very high.
•
Use only the specified power cord. If the power cord is damaged, it must be replaced by the
manufacturer or its service agent or a duly qualified person, in order to avoid risks.
•
Keep the power plug clean. Remove dust or dirt that collects in or around the plug. Dirty plugs can
cause fire or electric shock.
Do not pull the power cord to unplug the unit. Hold the plug firmly and remove it from the power
•
outlet. Pulling the cable directly can damage it, which can cause a fire or an electric shock.
Do not modify the length of the power cord or use an extension cord to power the unit.
•
Do not share the power outlet with other devices. An inadequate or insufficient power supply can
•
cause a fire or an electric shock.
•
The product must be properly grounded at the time of installation, otherwise an electric shock may
occur.
•
For all electrical maneuvers, follow all local and national wiring regulations, regulations and Installation
Manual. Connect the wires firmly and secure them firmly to prevent external forces from damaging the
terminal. Incorrect electrical connections can overheat and cause a fire, and can also cause a
discharge. All electrical connections must be made in accordance with the Electrical Connections
Diagram located on the panels of the indoor and outdoor units.
•
All wiring must be properly arranged to ensure that the control board cover can be closed properly. If
the control board cover is not closed properly, it can cause corrosion and cause the connection points
in the terminal to become hot, catch fire or cause an electric shock.
•
If you connect the power to the fixed wiring, you must incorporate a disconnection device of all the
poles that has at least 3 mm of free space towards all the poles, and with a leakage current that can
exceed 10 mA, having the device residual current (RCD) a nominal residual operating current that
does not exceed 30 mA, and the disconnection must be included in the fixed wiring in accordance with
established standards.
The air conditioning circuit board (PCB) is designed with a fuse to provide overcurrent protection. Fuse specifications
are printed on the circuit board, such as:
Indoor unit: T3.15AL / 250VAC, T5AL / 250VAC, T3.15A / 250VAC, T5A / 250VAC, etc.
Outdoor unit: T20A / 250VAC (units with Btu / h <= 18000), T30A / 250VAC (units with Btu / h> 18000)
Page 5
NOTE: For units with R-32 refrigerant, only the explosion-proof ceramic fuse can be used.
CLEANING AND MAINTENANCE WARNINGS
ELECTRICAL WARNINGS
TAKE NOTE OF THE FUSE SPECIFIATIONS
CAUTION