Electrical Connections - Saci [e]joy Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1

4. ELECTRICAL CONNECTIONS

Motor 3x230V
Signal
Outputs relay 1 and 2
Fan
Digital inputs 1 and 2
Pressure transducer
Screen Circuit
Description
Outputs that acts depending on how they have been
programmed. These outputs are potential free and
have a maximum load of 5 amperes at 230 Vac.
When wall-mounted, as there is no cooling from the
motor's own fan, the ventilation system of the wall
mounting shall be used for this cooling.
This output is at 24Vdc and is activated whenever the
pump is running.
Any potential free contact that will perform the
programmed functions can be connected to these
inputs.
N.B. Do not apply voltage to these inputs.
If it is connected, it will be used by the speed variator
to determine the pressure of the installation as well
as the pressure during the "BACK WASH" cycle.
20
Power supply
230Vac (1~ 50/60Hz)
Output relay 2
Output relay 1
Fan
Digital input 2
Digital input 1
Pressure transducer
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido