Shows a log of anomalies of the pump where the speed variator is connected, indicating the date, the time and the anomaly that occurred. This
information is very important for detecting possible anomalies in the functioning of the installation.
Par.
Description
12.01
RESET METERS
12.02
RESET ALARM HISTORY
12.03
FACTORY SETTINGS
11. ALARMS
Message
Indicates that the pressure entered in
PRESSURE WARNING:
the parameter (DIRTY FILTER WARNING
FILTER CLEANING
PRESSURE) has been exceeded.
Indicates excessive consumption in the
ALARM F01
motor.
OVERCURRENT
The motor is communicated or has burnt
out.
ALARM F02
Not all wires have been connected.
SHORT CIRCUIT
Internal fault in the variator.
The power module has reached a very high
ALARM F03
temperature, compromising its reliability.
EXCESS TEMPERATURE
OF THE MODULE
ALARM F04
The variator is not receiving electric current,
of is outside of the upper and lower limits.
INPUT
VOLTAGE
11. ALARM LOG
12. RESETS
VALUES
Units.
Default
Min.
NO
NO
NO
NO
NO
NO
Reasons
31
Max.
Enter YES to delete the voltage hours and the energy
YES
meter.
Enter YES to reset all the faults stored in the alarm
YES
history.
This parameter will remove all the settings entered
in the configuration of the variator, returning it to
YES
its initial status, as it was when installed for the first
time.
Solution(s)
Press the button BACK WASH and perform the steps indicated by
the filter cleaning wizard, as the system detects a high pressure
in the filter, probably due to excess soiling.
Check that the pump rotates freely with no obstructions.
Disconnect the motor from the variator and check that the
message disappears. If this is not the case, contact your nearest
technical service.
Check that all the cables of the motor are correctly connected to
the motor itself and also to the variator. Also supervise the correct
wiring of the frequency converter's power supply.
Contact your nearest technical service.
Ensure the ambient temperature does not exceed the extremes
set out in this manual.
Ensure the variator is properly ventilated; in this case check that
the pump has a fan and that the fan cover has been installed.
The electrical supply to the variator has been interrupted.
The electrical connection cable from the mains electricity to the
variator has been disconnected.