Ethernet module XPICO
Lantronix default settings:
Baud Rate 115200, Data Bits: 8,
Parity: None, Stop Bits: 1
J6: RESET (Reboot the module)
J7: INIT (reset to factory default
settings)
When the reader is switched on, the module red Led stays lit indicate the power supply.
The reader then waits for command. More details about reader's communication are available in the protocol specification SSCP:
Spec_Protocole_SSCP_UHF_INDUS_VX.X_US.pdf.
Mount with a 75 x 75 mm / 0.79 x 0.79 in VESA standard
mounting bracket M4x12 stainless steel screws provided
with mounting kit)
Or mount directly on a wall
Ø4x35 screws provided (VIS-TCZ 4x12).
SPECTRE UHF INDUSTRY
Installation procedure
Configuration of the interface board SMI / SLI
Communication protocol SMI / SLI
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1141X01 - Page 2 sur 12 - Ed. 24/07/2020
UHF SPECTRE INDUSTRY
Notice d'installation
Dimensions (mm/in) - SMI
Mounting - SMI
Two mounting possibilities:
Adjustable wall-mounted kit
(refer to the Installation Procedures
for KFX-UHF-08)
Wall
UHF SPECTRE INDUSTRY
Manual de instalación
End-of-line resistor (J8)
Use it (on RS485
connections) when the data
cable is 100 meters or more
long, and the
communication is degraded
(polluted signals, frame
errors etc.).
Adjustable pole-mounted kit
(refer to the Installation Procedures
for KFX-UHF-09)
US
FR
ES
Pole