In Projectors RGB to make the connections, open the power supply box by loosening the four screws on the upper cover.
To guarantee sealing, the cables should be inserted in the feeder using the packing glands provided.
The spotlights are supplied with a 4-wire 1.5mm2 Cu H07RNF cable. This cable is connected to the connection strips as
indicated in Figure 1, pag. 38.
Each wire should be connected to its corresponding terminal as follows:
The spotlight could be seriously damaged if the wires are connected in a different way than indicated.
Each spotlight must be connected to a different group of connection strips. If more than one spotlight is connected to the
same group of strips, the feeder could breakdown.
4.1. Types of connection between the feeder and the spotlights
· Individual connection: The spotlight is supplied with 2.5 metres of cable. If the spotlight is near the feeder it can be
connected directly to its connection strip.
If the distance between the spotlights and the feeder is more than 2.5 metres, the cables will have to be extended by
splicing them from the end of the cable supplied with the spotlight to the feeder.
To avoid voltage drops in the electrical cables, cables with appropriate sections should be used according to their length.
The spotlight cable should never be changed. The supplied cable guarantees a sealing degree of IP68. The use of a
different cable could cause a loss in sealing leading to the breakdown of the spotlight.
· Joint connection: A single link cable can be used to help in connecting the feeder with the spotlights.
R – Brown
B – Blue / Gray
G – Black
COM – Green / Yellow
Length (m)
0-20
20-30
30-50
3
Cable section
2
1.5 mm
Cu
2
2.5 mm
Cu
2
4 mm
Cu